Device LOP for nuclear level transmitter/switch
list of properties characterizing a nuclear level transmitter or switch
Hierarchy#
Ancestors (top) → ABE746 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes4#
Declared properties16#
@number of additional components
@number of outputs
reference to block ABC080
reference to block ABC100
reference to block ABC156
reference to block ABC165
reference to block ABC200
reference to block 0112/2///61360_7#CAA014
reference to block ABC458
reference to block ABC523
reference to block ABF924
reference to block ABG127
reference to block ABG320
ABG929ref. Mechanical and electrical construction [nuclear level transmitter/switch]CLASS_REFERENCE_TYPE(0112/2///61987#ABG369)reference to block ABG369
reference to block ABH348
reference to block ABC255
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2014-12-17
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00018
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-18
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABE746
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2014-12-17
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Geräte-Merkmalleiste für radiometrischen Füllstandmessumformer/Schalter
- MDC_P004.en
- Device LOP for nuclear level transmitter/switch
- MDC_P006.de
- Merkmalleiste, die einen radiometrischen Füllstandmessumformer oder Schalter kennzeichnet
- MDC_P006.en
- list of properties characterizing a nuclear level transmitter or switch
- MDC_P010
- 0112/2///61987#ABV504
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABC899,0112/2///61987#ABC730,0112/2///61987#ABU857,0112/2///61987#ABG484,0112/2///61987#ABB206,0112/2///61987#ABG687,0112/2///61987#ABC830,0112/2///61987#ABH349,0112/2///61987#ABG880,0112/2///61987#ABG929,0112/2///61987#ABD088,0112/2///61987#ABD153,0112/2///61987#ABC786,0112/2///61987#ABC795,0112/2///61987#ABA293,0112/2///61987#ABC710}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.