Ullage measurement
properties characterizing an ullage measurement
Hierarchy#
Ancestors (top) → ABE888 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties14#
density used to calculate variables to reference conditions
absolute pressure used to calculate variables to reference conditions
gauge pressure used to calculate variables to reference conditions
phenomenon serving as the basis of a measurement
temperature used to calculate variables to reference conditions
process fluid used to calculate variables to reference conditions or to state variables under reference conditions
solid density used to calculate variables to reference conditions or to state variables under reference conditions
relative permittivity used to calculate variables to reference conditions or to state variables under reference conditions
electrical conductivity used to calculate variables to reference conditions or to state variables under reference conditions
grain size used to calculate variables to reference conditions or to state variables under reference conditions
type of tank used to calculate variables to reference conditions or to state variables under reference conditions
plain text describing vessel conditions used to calculate variables to reference conditions or to state variables under reference conditions
plain text describing deployment conditions used to calculate variables to reference conditions or to state variables under reference conditions
reference to block ABE901
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Synonyms
- Freeboard measurement
- Remark
- Polymorphic element: ABE888, Id: 3
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2018-03-28
- Current version: 2018-03-28
- Current revision: 2018-03-28
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (24 keys from source .xls) — click to expand
- C002
- C00018
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABE888
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2018-03-28
- MDC_P003_2
- 2018-03-28
- MDC_P003_3
- 2018-03-28
- MDC_P004.de
- Freiraummessung
- MDC_P004.en
- Ullage measurement
- MDC_P006.de
- Merkmale, die eine Freiraummessung kennzeichnen
- MDC_P006.en
- properties characterizing an ullage measurement
- MDC_P007.en
- Freeboard measurement
- MDC_P009.en
- Polymorphic element: ABE888, Id: 3
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB015,0112/2///61987#ABF677,0112/2///61987#ABA324,0112/2///61987#ABE890,0112/2///61987#ABA328,0112/2///61987#ABA330,0112/2///61987#ABB781,0112/2///61987#ABE889,0112/2///61987#ABE891,0112/2///61987#ABE892,0112/2///61987#ABE893,0112/2///61987#ABE894,0112/2///61987#ABE895,0112/2///61987#ABE896}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.