Dynamic behaviour of point level
properties characterizing the dynamic response of a point level devices
Hierarchy#
Ancestors (top) → ABE995 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties9#
time delay between the passing of a limit value and the resulting switching action
time duration between two successive measurements
hysteresis of the trip point of a point level device, referenced to the horizontal line for rising level of process material
angular hysteresis of the trip point of a point level device mounted at an angle as referenced to the horizontal
shortest time delay between triggering and the resulting switching action
greatest time delay between triggering and the resulting switching action
response time of a level measuring device in the case of rising fluid level
response time of a level measuring device in the case of falling fluid level
change of level that must be applied at a point level device before the output signal changes
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2018-03-28
- Current version: 2018-03-28
- Current revision: 2018-03-28
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00018
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABE995
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2018-03-28
- MDC_P003_2
- 2018-03-28
- MDC_P003_3
- 2018-03-28
- MDC_P004.de
- Dynamisches Verhalten von Grenzstand
- MDC_P004.en
- Dynamic behaviour of point level
- MDC_P006.de
- Merkmale, die das dynamische Verhalten einer Grenzstandmesseinrichtung kennzeichnen
- MDC_P006.en
- properties characterizing the dynamic response of a point level devices
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABE996,0112/2///61987#ABH420,0112/2///61987#ABE997,0112/2///61987#ABF271,0112/2///61987#ABF272,0112/2///61987#ABA457,0112/2///61987#ABE998,0112/2///61987#ABE999,0112/2///61987#ABB718}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.