Structural design of a bypass/measuring chamber
properties characterizing the constructional details of a bypass or the measuring chamber
Hierarchy#
Ancestors (top) → ABF023 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties26#
construction standard used for the engineering and fabrication of a component or connection
alphanumeric designation of size for components of a pipe work system, which is used for reference purposes
alphanumeric designation of a pressure allowable within a piping system or piece of equipment, which is used for reference purposes
internal diameter of a component measured at the point of maximum restriction
classification of a protective coating according to the type and finish of the coating material
material of a protective lining that prevents the contact of a fluid with the material from which the equipment is made
@number of lines or nozzles
reference to block ABC322
reference to block ABC353
vertical distance between two process connections
length available within a device
classification of a pipe according to its mechanical design
classification of a vent valve according to its mechanical design
classification of the drain valve according to its mechanical design
classification of the shut-off valve located at the upper part of a measuring chamber according to its mechanical construction
classification of the shut-off valve located at the lower side of a measuring chamber according to its mechanical construction
classification of a bypass/measuring chamber according to its constructional design
position of a lower connection regarding to the device in its mounting position
position of an upper connection regarding to the device in its mounting position
classification of a head according to its constructional design
orientation of a head with respect to the horizontal
vertical distance between two process connections
given radius of the weld pad
position where the support plate is mounted
offset orientation of a valve relative to the valve main axis
mounting orientation of a valve relative to the valve main axis
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2014-12-17
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00018
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABF023
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2014-12-17
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Konstruktiver Aufbau eines Bypass/einer Messkammer
- MDC_P004.en
- Structural design of a bypass/measuring chamber
- MDC_P006.de
- Merkmale, die die konstruktiven Details eines Bypass oder einer Messkammer kennzeichnen
- MDC_P006.en
- properties characterizing the constructional details of a bypass or the measuring chamber
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABH406,0112/2///61987#ABB335,0112/2///61987#ABC952,0112/2///61987#ABA576,0112/2///61987#ABA591,0112/2///61987#ABA910,0112/2///61987#ABF021,0112/2///61987#ABE885,0112/2///61987#ABH416,0112/2///61987#ABH409,0112/2///61987#ABH410,0112/2///61987#ABH407,0112/2///61987#ABH408,0112/2///61987#ABC983,0112/2///61987#ABA145,0112/2///61987#ABF022,0112/2///61987#ABB120,0112/2///61987#ABH483,0112/2///61987#ABH484,0112/2///61987#ABH485,0112/2///61987#ABH486,0112/2///61987#ABA917,0112/2///61987#ABF274,0112/2///61987#ABF275,0112/2///61987#ABF218,0112/2///61987#ABF219}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.