Single electrode probe
properties characterizing a single electrode used as the probe of a conductance level transmitter or switch
Hierarchy#
Ancestors (top) → ABF155 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties18#
typical or rated electrical or mechanical vibration frequency at which the device operates
length of a probe, including the bottom weight where applicable, measured from the bottom of the process connection
length of a probe, including the bottom weight where applicable, measured from the bottom of the process connection
classification of a probe according to its method of fixation
classification of the insulation of an electrical probe according to its mechanical construction
largest diameter of a probe, where appropriate excluding the bottom weight
material of which the probe insulation made
length of that part of a probe, measured from the bottom of the process connection, that is electrically insulated
classification of a build-up compensation system according to the method used to compensate
length of that part of a probe that is used to provide a measurement
length of a part intended to suppress measuring errors caused by build-up at an electrode
length of a tube serving as a grounding electrode
inside diameter of a tube serving as a grounding electrode
outside diameter of a tube serving as a grounding electrode
classification of a probe surface finish according to the method used to achieve it
reference to block ABF142
reference to block ABF148
ABU883reference to Material of grounding tube/grounding electrodeCLASS_REFERENCE_TYPE(0112/2///61987#ABV033)reference to block ABV033
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2018-03-28
- Current version: 2018-03-28
- Current revision: 2018-03-28
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00018
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABF155
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2018-03-28
- MDC_P003_2
- 2018-03-28
- MDC_P003_3
- 2018-03-28
- MDC_P004.de
- Einzelelektrodensonde
- MDC_P004.en
- Single electrode probe
- MDC_P006.de
- Merkmale, die einzelne Elektrode als Sensor eines konduktiven Füllstandmessumformers und konduktiven Grenzstandschalters kennzeichnen
- MDC_P006.en
- properties characterizing a single electrode used as the probe of a conductance level transmitter or switch
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABF138,0112/2///61987#ABF139,0112/2///61987#ABF138,0112/2///61987#ABF140,0112/2///61987#ABF141,0112/2///61987#ABF733,0112/2///61987#ABF153,0112/2///61987#ABF144,0112/2///61987#ABF143,0112/2///61987#ABF146,0112/2///61987#ABF145,0112/2///61987#ABF147,0112/2///61987#ABF734,0112/2///61987#ABB028,0112/2///61987#ABF149,0112/2///61987#ABF150,0112/2///61987#ABF151,0112/2///61987#ABU883}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.