Structural design of a rotary paddle switch
properties characterizing the constructional details of a rotary paddle switch
Hierarchy#
Ancestors (top) → ABF191 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties24#
precautions taken or to be taken during manufacture of the device regarding wetted parts to ensure its safe operation under special operation conditions
classification of a component surface finish according to the method used to achieve it
tightness of a pressure or vacuum housing expressed in terms of the leakage rate to or from its environment
classification of a seal according to its construction
@number of additional wetted parts materials
finishing specification of a surface expressed as roughness, either as a maximum depth or in a standardized roughness dimension
@number of material of wetted inner seals
classification of a feedthrough according to the mechanical design
reference to block ABC339
reference to block ABC403
overall length of that part of a device or component to be found within a containment
insertion length of a shaft or a cable
length of that part of a probe or measuring assembly that is used to increase the distance between the sensing element and transmitter housing in order to avoid overheating of the electronics in high temperature applications
smallest inside diameter of a nozzle which still allows a device or a device component to be mounted or to operate within specifications
largest inside length a nozzle which still allows a device or a device component to be mounted or to operate within specifications
classification of an extension according to its geometrical shape
reference to block ABF192
reference to block ABF197
reference to block ABF199
classification of a shaft coupling according to its mechanical design
classification of a shaft guarding according to its mechanical design
classification of a rotary paddle switch motor according to its mode of operation
classification of a rotary paddle switch according to its mechanical construction
reference to block ABU458
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2014-12-17
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00018
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABF191
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2014-12-17
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Konstruktiver Aufbau eines Drehflügel-Grenzstandschalters
- MDC_P004.en
- Structural design of a rotary paddle switch
- MDC_P006.de
- Merkmale, die die konstruktiven Details eines Drehflügel-Grenzstandschalters kennzeichnen
- MDC_P006.en
- properties characterizing the constructional details of a rotary paddle switch
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABU164,0112/2///61987#ABH487,0112/2///61987#ABF748,0112/2///61987#ABF198,0112/2///61987#ABF750,0112/2///61987#ABF512,0112/2///61987#ABF200,0112/2///61987#ABF751,0112/2///61987#ABE884,0112/2///61987#ABH451,0112/2///61987#ABH452,0112/2///61987#ABH453,0112/2///61987#ABF201,0112/2///61987#ABF202,0112/2///61987#ABC028,0112/2///61987#ABB521,0112/2///61987#ABA147,0112/2///61987#ABA633,0112/2///61987#ABB140,0112/2///61987#ABB396,0112/2///61987#ABB915,0112/2///61987#ABD033,0112/2///61987#ABB457,0112/2///61987#ABC969}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.