Structural design of a thermowell

0112/2///61987#ABF319

properties characterizing the constructional details of a thermowell

Hierarchy#

Ancestors (top) → ABF319 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties33#

33 / 33

precautions taken or to be taken during manufacture of the device regarding wetted parts to ensure its safe operation under special operation conditions

ABA633type of surface finishENUM_STRING_TYPE

classification of a component surface finish according to the method used to achieve it

ABA910inside diameterREAL_MEASURE_TYPE

internal diameter of a component measured at the point of maximum restriction

ABB140leak tightness to exteriorREAL_MEASURE_TYPE

tightness of a pressure or vacuum housing expressed in terms of the leakage rate to or from its environment

ABB396type of sealTRANSLATABLE_STRING_TYPE

classification of a seal according to its construction

ABB521surface roughness of wetted partsREAL_MEASURE_TYPE

finishing specification of a surface expressed as roughness, either as a maximum depth or in a standardized roughness dimension

ABB932outside diameterREAL_MEASURE_TYPE

actual external diameter of a circular or cylindrical object

ABC028type of feedthroughTRANSLATABLE_STRING_TYPE

classification of a feedthrough according to the mechanical design

ABE884insertion lengthREAL_MEASURE_TYPE

overall length of that part of a device or component to be found within a containment

ABF322type of thermowellTRANSLATABLE_STRING_TYPE

classification of a thermowell according to a mechanical design not defined in a standard or by additional information to the standard design

ABF323nominal lengthREAL_MEASURE_TYPE

length specified by the manufacturer for a device or device component, which is used for reference purposes

ABF330material of coatingTRANSLATABLE_STRING_TYPE

material of a protective coating that prevents the contact of a fluid with the material from which the equipment is made

ABF510natural frequencyREAL_MEASURE_TYPE

any frequency at which free oscillation can exist in a physical system when the excitation has been removed

ABF511yield strengthREAL_MEASURE_TYPE

stress at which a material begins to deform plastically

ABH374type of shankENUM_STRING_TYPE

classification of a shank according to its constructional design

ABH375length of lagging extensionREAL_MEASURE_TYPE

length of that part of a fitting, if appropriate without the flange thickness, that is lies outside of the equipment

ABH376type of cap or plugTRANSLATABLE_STRING_TYPE

classification of a cap or plug according to its constructional design

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
1
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
SC65E – IEC 61987
Change request
C00019
Dates
  • Original: 2014-12-17
  • Current version: 2016-05-24
  • Current revision: 2016-05-24

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (22 keys from source .xls) — click to expand
C002
C00019
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C018.de
2014-12-17
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABF319
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2018-03-28
MDC_P003_1
2014-12-17
MDC_P003_2
2016-05-24
MDC_P003_3
2016-05-24
MDC_P004.de
Konstruktiver Aufbau eines Thermometer-Schutzrohrs
MDC_P004.en
Structural design of a thermowell
MDC_P006.de
Merkmale, die die konstruktiven Details eines Thermometer-Schutzrohrs kennzeichnen
MDC_P006.en
properties characterizing the constructional details of a thermowell
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABU431,0112/2///61987#ABF321,0112/2///61987#ABF320,0112/2///61987#ABF322,0112/2///61987#ABH374,0112/2///61987#ABF331,0112/2///61987#ABF333,0112/2///61987#ABF332,0112/2///61987#ABB932,0112/2///61987#ABA910,0112/2///61987#ABF323,0112/2///61987#ABE884,0112/2///61987#ABH375,0112/2///61987#ABF324,0112/2///61987#ABF510,0112/2///61987#ABC983,0112/2///61987#ABF511,0112/2///61987#ABF775,0112/2///61987#ABF776,0112/2///61987#ABF777,0112/2///61987#ABF330,0112/2///61987#ABF508,0112/2///61987#ABH376,0112/2///61987#ABH377,0112/2///61987#ABB521,0112/2///61987#ABA147,0112/2///61987#ABA633,0112/2///61987#ABB140,0112/2///61987#ABB396,0112/2///61987#ABV165,0112/2///61987#ABC028,0112/2///61987#ABB457,0112/2///61987#ABC969}