Structural design of a hydrostatic pressure level transmitter
properties characterizing the constructional details of a hydrostatic pressure level transmitter
Hierarchy#
Ancestors (top) → ABF341 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties28#
precautions taken or to be taken during manufacture of the device regarding wetted parts to ensure its safe operation under special operation conditions
classification of a component surface finish according to the method used to achieve it
classification of a pressure sensor according to the measuring principle used to sense pressure
material of which the gasket of the diaphragm sealing the fill fluid inside a pressure transmitter is made
cardinality property for process connection
tightness of a pressure or vacuum housing expressed in terms of the leakage rate to or from its environment
classification of a seal according to its construction
fluid used to fill an internal cavity in a device or component
location of a vent hole in a pipe, flange, union or orifice plate
@number of additional wetted parts materials
@number of material of wetted inner seals
classification of a feedthrough according to the mechanical design
reference to block ABC339
reference to block ABC360
reference to block ABC377
ABD023reference to Material of separating/measuring diaphragmCLASS_REFERENCE_TYPE(0112/2///61987#ABC393)reference to block ABC393
reference to block ABC401
reference to block ABC403
classification of mounting of a device according to place it is mounted
technical method by which the compensation is achieved
classification of a hydrostatic pressure level measurement according to the method used to measure pressure difference
classification of a pressure transmitter according to the method of mounting
classification of the low pressure process connection of a hydrostatic level pressure transmitter according to its mechanical design
classification of the high pressure process connection of a hydrostatic level pressure transmitter according to its mechanical design
reference to block ABF348
lowest span to which a differential pressure measurement instrument can be adjusted
highest span to which a differential pressure measurement instrument can be adjusted
reference to block ABU458
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2014-12-17
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00018
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABF341
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2014-12-17
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Konstruktiver Aufbau eines hydrostatischen Füllstandmessumformers
- MDC_P004.en
- Structural design of a hydrostatic pressure level transmitter
- MDC_P006.de
- Merkmale, die die konstruktiven Details eines hydrostatischen Füllstandmessumformers kennzeichnen
- MDC_P006.en
- properties characterizing the constructional details of a hydrostatic pressure level transmitter
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB102,0112/2///61987#ABU453,0112/2///61987#ABF344,0112/2///61987#ABF345,0112/2///61987#ABB048,0112/2///61987#ABD465,0112/2///61987#ABF346,0112/2///61987#ABF347,0112/2///61987#ABE872,0112/2///61987#ABH403,0112/2///61987#ABH404,0112/2///61987#ABD023,0112/2///61987#ABB100,0112/2///61987#ABB397,0112/2///61987#ABF783,0112/2///61987#ABB419,0112/2///61987#ABD031,0112/2///61987#ABC990,0112/2///61987#ABD007,0112/2///61987#ABA147,0112/2///61987#ABA633,0112/2///61987#ABB140,0112/2///61987#ABC028,0112/2///61987#ABB396,0112/2///61987#ABB915,0112/2///61987#ABD033,0112/2///61987#ABB457,0112/2///61987#ABC969}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.