Displacer
properties characterizing the displacer
Hierarchy#
Ancestors (top) → ABF360 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties18#
mass of a device or component in full working order
alphanumeric designation of a pressure allowable within a piping system or piece of equipment, which is used for reference purposes
horizontal distance between the front and back of an object when standing in its normal position of use or the distance from end to end of a long, thin object
ratio of the density of a liquid or a solid to the density of water at reference temperature
mass of a body divided by its volume or the mass of the amount of a substance divided by its volume
maximum permitted test pressure that can be or is applied without changing the device specification
actual external diameter of a circular or cylindrical object
geometrical form of a float or a displacer
pressure of a gas or liquid within a closed vessel expressed as a gauge pressure
number of segments building up a complete displacer
length of a segment of a displacer split up into parts of equal length
alphanumeric character sequence identifying a displacer
classification of a displacer according to its mechanical design
reference to block ABF363
reference to block ABF364
reference to block ABF365
reference to block ABF366
reference to block ABF367
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2018-03-28
- Current version: 2018-03-28
- Current revision: 2018-03-28
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00018
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABF360
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2018-03-28
- MDC_P003_2
- 2018-03-28
- MDC_P003_3
- 2018-03-28
- MDC_P004.de
- Verdränger
- MDC_P004.en
- Displacer
- MDC_P006.de
- Merkmale, die den Verdränger kennzeichnen
- MDC_P006.en
- properties characterizing the displacer
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABF430,0112/2///61987#ABF373,0112/2///61987#ABB932,0112/2///61987#ABA640,0112/2///61987#ABA553,0112/2///61987#ABF031,0112/2///61987#ABB319,0112/2///61987#ABB297,0112/2///61987#ABA591,0112/2///61987#ABB893,0112/2///61987#ABF034,0112/2///61987#ABF791,0112/2///61987#ABF792,0112/2///61987#ABF361,0112/2///61987#ABF362,0112/2///61987#ABF788,0112/2///61987#ABF789,0112/2///61987#ABF790}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.