Structural design of a connection head
properties characterizing the constructional details of a connection head
Hierarchy#
Ancestors (top) → ABF380 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties34#
degree of ingress protection offered by a housing or enclosure
extent of protection provided by an enclosure against access to hazardous parts, against ingress of solid foreign objects and/or ingress of water and verified by standardized test methods
vertical distance between the top and bottom of an object when standing in its normal position of use
colour of a component
set of specific measures applied to equipment to avoid ignition of a surrounding explosive atmosphere
internal diameter of a component measured at the point of maximum restriction
classification of a protective coating according to the type and finish of the coating material
@number of electrical terminals
standard to which a statement on an enclosure protection type or class refers
actual external diameter of a circular or cylindrical object
@number of cable/conduit entries
@number of equipotential bonding connections
reference to block ABC149
reference to block ABC220
reference to block ABC231
material from which the window is made
classification of a connection to a thermowell extension according to its fabricated form
classification of a connection to an insert according to its fabricated form
classification of a connection to a thermowell according to its fabricated form
classification of a connection head according to its constructional design or standardized form
standard on which the design of a connection head for temperature measurement devices is based
distance between the center line of the connection head to the end of the cable gland
classification of a head-mounted transmitter according to its constructional design or standardized form
standard on which the design of a head-mounted transmitter is based
diameter of the head-mounted transmitter at its widest point or the largest diameter which is allowed
number of head-mounted transmitters which can be build into a connection head
classification of a head-mounted transmitter according to the mounting location
classification of a cover of the connection head according to its method of fastening
classification of a cover of the connection head according to its method of securing against loss of the cover
material of a connection head is made
material of a connection head seal is made
material of mounting parts are made
classification of a connection to a head-mounted transmitter according to its fabricated form
colour of a cap
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00019- Dates
- Original: 2014-12-17
- Current version: 2016-05-24
- Current revision: 2016-05-24
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00019
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABF380
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2014-12-17
- MDC_P003_2
- 2016-05-24
- MDC_P003_3
- 2016-05-24
- MDC_P004.de
- Konstruktiver Aufbau eines Anschlusskopfs
- MDC_P004.en
- Structural design of a connection head
- MDC_P006.de
- Merkmale, die die konstruktiven Details eines Anschlusskopfs kennzeichnen
- MDC_P006.en
- properties characterizing the constructional details of a connection head
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABF381,0112/2///61987#ABF382,0112/2///61987#ABF379,0112/2///61987#ABF331,0112/2///61987#ABF332,0112/2///61987#ABF394,0112/2///61987#ABF384,0112/2///61987#ABF385,0112/2///61987#ABF386,0112/2///61987#ABF387,0112/2///61987#ABF388,0112/2///61987#ABB932,0112/2///61987#ABA910,0112/2///61987#ABA574,0112/2///61987#ABF383,0112/2///61987#ABF391,0112/2///61987#ABF019,0112/2///61987#ABA582,0112/2///61987#ABA917,0112/2///61987#ABA589,0112/2///61987#ABA558,0112/2///61987#ABA179,0112/2///61987#ABB386,0112/2///61987#ABF389,0112/2///61987#ABF390,0112/2///61987#ABF392,0112/2///61987#ABF395,0112/2///61987#ABF393,0112/2///61987#ABB103,0112/2///61987#ABC850,0112/2///61987#ABC010,0112/2///61987#ABC779,0112/2///61987#ABC012,0112/2///61987#ABC861}
Version history1#