Structural design of separate temperature transmitter
properties characterizing the constructional details of a separate temperature transmitter
Hierarchy#
Ancestors (top) → ABF396 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties15#
frequency characteristics of a line filter used to block interference
maximum width of a round object taken as a straight line passing through its center
setting of the sensing element type that is or should be connected to the device
classification of a connection to a thermowell extension according to its fabricated form
classification of a connection to an insert according to its fabricated form
classification of a connection to a connection head according to its fabricated form
classification of a connection to a thermowell according to its fabricated form
classification of a head-mounted transmitter according to its constructional design or standardized form
standard on which the design of a head-mounted transmitter is based
classification of a separate temperature transmitter according to its mounting location
@number of RTD/resistance measurements
@number of thermocouple/voltage measurements
classification of a sensor backup according to its kind of switching to the backup sensor
reference to block ABF398
reference to block ABF399
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00019- Dates
- Original: 2014-12-17
- Current version: 2016-05-24
- Current revision: 2016-05-24
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00019
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABF396
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2014-12-17
- MDC_P003_2
- 2016-05-24
- MDC_P003_3
- 2016-05-24
- MDC_P004.de
- Konstruktiver Aufbau eines separaten Temperatur-Messumformers
- MDC_P004.en
- Structural design of separate temperature transmitter
- MDC_P006.de
- Merkmale, die die konstruktiven Details eines separaten Temperatur-Messumformers kennzeichnen
- MDC_P006.en
- properties characterizing the constructional details of a separate temperature transmitter
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABF397,0112/2///61987#ABF384,0112/2///61987#ABF385,0112/2///61987#ABF288,0112/2///61987#ABF379,0112/2///61987#ABF331,0112/2///61987#ABF333,0112/2///61987#ABF332,0112/2///61987#ABB952,0112/2///61987#ABF401,0112/2///61987#ABF801,0112/2///61987#ABF402,0112/2///61987#ABF802,0112/2///61987#ABB260,0112/2///61987#ABF404}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.