Skip to content
OpenCDD
classITEM_CLASSv1rev 12018-03-20

Structural design of a plumb bob level transmitter

0112/2///61987#ABF431

properties characterizing the constructional details of a plumb bob level transmitter

Hierarchy#

Ancestors (top) → ABF431 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties23#

23 / 23

precautions taken or to be taken during manufacture of the device regarding wetted parts to ensure its safe operation under special operation conditions

ABA633type of surface finishENUM_STRING_TYPE

classification of a component surface finish according to the method used to achieve it

ABB140leak tightness to exteriorREAL_MEASURE_TYPE

tightness of a pressure or vacuum housing expressed in terms of the leakage rate to or from its environment

ABB396type of sealTRANSLATABLE_STRING_TYPE

classification of a seal according to its construction

ABB521surface roughness of wetted partsREAL_MEASURE_TYPE

finishing specification of a surface expressed as roughness, either as a maximum depth or in a standardized roughness dimension

ABC028type of feedthroughTRANSLATABLE_STRING_TYPE

classification of a feedthrough according to the mechanical design

ABF181minimum blocking distanceREAL_MEASURE_TYPE

smallest extent of a zone that exists immediately below a probe, within which measurement is not possible

ABF439type of sensing weightTRANSLATABLE_STRING_TYPE

classification of a sensor weight according to its mechanical design

ABF441length of cable/tapeREAL_MEASURE_TYPE

length of a cable or tape not including any devices or components attached

ABF443style of cable/tape wiperTRANSLATABLE_STRING_TYPE

classification of a cable or tape wiper to clean the cable or tape according to its mechanical design

ABF445maximum nozzle heightREAL_MEASURE_TYPE

largest inside height a nozzle which still allows a device or a device component to be mounted or to operate within specifications

ABF449minimum move distanceREAL_MEASURE_TYPE

smallest distance a probe must travel in order to enable the device function

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
1
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
SC65E – IEC 61987
Change request
C00018
Dates
  • Original: 2014-12-17
  • Current version: 2018-03-20
  • Current revision: 2018-03-20

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (22 keys from source .xls) — click to expand
C002
C00018
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C018.de
2014-12-17
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABF431
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2018-03-28
MDC_P003_1
2014-12-17
MDC_P003_2
2018-03-20
MDC_P003_3
2018-03-20
MDC_P004.de
Konstruktiver Aufbau eines Lotsystems
MDC_P004.en
Structural design of a plumb bob level transmitter
MDC_P006.de
Merkmale, die die konstruktiven Details eines Lotsystems zu Füllstandmessung kennzeichnen
MDC_P006.en
properties characterizing the constructional details of a plumb bob level transmitter
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABU164,0112/2///61987#ABF439,0112/2///61987#ABF440,0112/2///61987#ABF441,0112/2///61987#ABF442,0112/2///61987#ABF443,0112/2///61987#ABF444,0112/2///61987#ABF445,0112/2///61987#ABF446,0112/2///61987#ABF447,0112/2///61987#ABF448,0112/2///61987#ABF181,0112/2///61987#ABF449,0112/2///61987#ABB521,0112/2///61987#ABA147,0112/2///61987#ABA633,0112/2///61987#ABB140,0112/2///61987#ABC028,0112/2///61987#ABB396,0112/2///61987#ABB915,0112/2///61987#ABD033,0112/2///61987#ABB457,0112/2///61987#ABC969}

Version history1#

  1. Current rev 01
    28 Mar 2018 · 07:26 UTC by BATCH 00000762
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.