Dynamic behaviour [4]
properties characterizing the dynamic response of a device output
Hierarchy#
Ancestors (top) → ABG316 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties10#
time duration for the output to reach and remain within the manufacturer's specified limits with a 90% input signal applied to the device
drift in output monitored for 30 days with a constant input signal of 90 % of span
time interval between the instant when the variation of an input variable is produced and the instant when the consequent variation of the output variable starts
for a step response, duration of the time interval between the instant when the output variable reaches a small, specified percentage of the difference between the final and the initial steady state vales and the instant when it reaches for the first time a large, specified percentage of the same steady state difference
time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 90% of its final steady state value
time required to complete 63.2% of the total rise or decay of the output of a first-order linear system, initiated by a step or an impulse to the input
time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 63% of its final steady state value
drift in zero or lower range-limit value monitored for 30 days with a constant input signal of 90% of span
time duration between two successive measurements
time of collection of data to produce a resulting mean value
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00019- Dates
- Original: 2017-09-22
- Current version: 2017-09-22
- Current revision: 2017-09-22
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (27 keys from source .xls) — click to expand
- C002
- C00019
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-17
- C018.fr
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- C019.fr
- UTE
- MDC_P001_5
- 0112/2///61987#ABG316
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2017-09-22
- MDC_P003_2
- 2017-09-22
- MDC_P003_3
- 2017-09-22
- MDC_P004.de
- Dynamisches Verhalten
- MDC_P004.en
- Dynamic behaviour [4]
- MDC_P004.fr
- Comportement dynamique
- MDC_P006.de
- Merkmale, die das dynamische Verhalten eines Geräteausgangs kennzeichnen
- MDC_P006.en
- properties characterizing the dynamic response of a device output
- MDC_P006.fr
- propriétés caractérisant la réponse dynamique d’une sortie d’appareil
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABA569,0112/2///61987#ABB717,0112/2///61987#ABA570,0112/2///61987#ABB000,0112/2///61987#ABB077,0112/2///61987#ABB078,0112/2///61987#ABB550,0112/2///61987#ABB079,0112/2///61987#ABB718,0112/2///61987#ABB719}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.