Fluid phase design conditions
properties characterizing the normal range of process conditions, separated for individual phases, for which a device is to be designed and operate within its specifications
Hierarchy#
Ancestors (top) → ABH071 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties33#
highest dynamic viscosity for which a device is or should be designed to operate within its specified limits
highest kinematic viscosity for which a device is or should be designed to operate within its specified limits
lowest fluid velocity for which a device is or should be designed to operate within its specified limits
highest fluid velocity for which a device is or should be designed to operate within its specified limits
lowest electrical conductivity for which a device is or should be designed to operate within its specified limits
lowest thermal conductivity for which a device is or should be designed to operate within its specified limits
lowest actual density for which a device is or should be designed to operate within its specified limits
highest actual density for which a device is or should be designed to operate within its specified limits
highest electrical conductivity for which a device is or should be designed to operate within its specified limits
highest thermal conductivity for which a device is or should be designed to operate within its specified limits
temperature of the liquid on which a statement of relative density is based
temperature of the water on which a statement of specific gravity is based
lowest solids content expressed as mass fraction for which a device is or should be designed to operate within its specified limits
highest solids content expressed as mass fraction for which a device is or should be designed to operate within its specified limits
lowest relative permittivity for which a device is or should be designed to operate within its specified limits
smallest particle size for which a device is or should be designed to operate within its specified limits
greatest particle size for which a device is or should be designed to operate within its specified limits
highest relative permittivity for which a device is or should be designed to operate within its specified limits
classification of a fluid phase according to its state
location of a fluid layer within a number of layers
temperature at which the relative permittivity of a material was determined
greatest thickness of buildup at the walls of a containment of a probe that is expected to occur
lowest phase height for which a device is or must be designed to operate within its specified limits
highest phase height for which a device is or must be designed to operate within its specified limits
lowest specific gravity for which a device is or must be designed to operate within its specified limits
highest specific gravity for which a device is or must be designed to operate within its specified limits
lowest bulk density for which a device is or must be designed to operate within its specified limits
highest bulk density for which a device is or must be designed to operate within its specified limits
lowest water content as mass fraction for which a device is or must be designed to operate within its specified limits
highest water content as mass fraction for which a device is or must be designed to operate within its specified limits
greatest angle of repose for which a device is or must be designed to operate within its specified limits
lowest refractive for which a device is or must be designed to operate within its specified limits
highest refractive for which a device is or must be designed to operate within its specified limits
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2018-03-28
- Current version: 2018-03-28
- Current revision: 2018-03-28
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00018
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABH071
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2018-03-28
- MDC_P003_2
- 2018-03-28
- MDC_P003_3
- 2018-03-28
- MDC_P004.de
- Auslegungsbedingung für einzelne Phasen
- MDC_P004.en
- Fluid phase design conditions
- MDC_P006.de
- Merkmale, die den Normalbereich der Prozessbedingungen getrennt nach einzelnen Phasen kennzeichnen, für die ein Gerät auszulegen ist und innerhalb deren Spezifikationen es betrieben wird
- MDC_P006.en
- properties characterizing the normal range of process conditions, separated for individual phases, for which a device is to be designed and operate within its specifications
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABD753,0112/2///61987#ABH060,0112/2///61987#ABH072,0112/2///61987#ABH073,0112/2///61987#ABB055,0112/2///61987#ABB056,0112/2///61987#ABH074,0112/2///61987#ABH075,0112/2///61987#ABB298,0112/2///61987#ABB299,0112/2///61987#ABH076,0112/2///61987#ABH077,0112/2///61987#ABA110,0112/2///61987#ABA111,0112/2///61987#ABH066,0112/2///61987#ABB434,0112/2///61987#ABB435,0112/2///61987#ABH078,0112/2///61987#ABH079,0112/2///61987#ABH080,0112/2///61987#ABD426,0112/2///61987#ABD427,0112/2///61987#ABB027,0112/2///61987#ABB233,0112/2///61987#ABD422,0112/2///61987#ABD428,0112/2///61987#ABH063,0112/2///61987#ABB035,0112/2///61987#ABB259,0112/2///61987#ABH081,0112/2///61987#ABH082,0112/2///61987#ABA112,0112/2///61987#ABA114}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.