Parameters of differential pressure level measurement
properties characterizing a differential pressure level measurement
Hierarchy#
Ancestors (top) → ABH168 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties18#
temperature of the liquid on which a statement of relative density is based
temperature of the water on which a statement of specific gravity is based
for an elevated or suppressed-zero range, amount by which the measured variable is above (zero point elevation) or below (zero point suppression) the lower range value
classification of a pressure transmitter or the pressure gauge according to its mounting position
vertical distance between the high/single pressure process connection and the sensing element of the pressure transmitter or pressure gauge
vertical distance between the low pressure process connection and the sensing element of the pressure transmitter or pressure gauge
distance between a liquid level at upper range limit and the lower process connection of the pressure transmitter or pressure gauge
distance between a liquid level at lower range limit and the lower process connection of a pressure transmitter or pressure gauge
calculated height of a liquid resulting from the measured differential pressure and the total effective fluid density
vertical distance between two process connections
length of a liquid filled capillary that has or should have a remote sealed pressure transmitter at the low pressure side
length of a liquid filled capillary that has or should have a remote sealed pressure transmitter at the high pressure side
density of the liquid in a filled wet leg at the high pressure side of a differential pressure transmitter
density of the liquid in a filled wet leg at the low pressure side of a differential pressure transmitter
specific gravity of the liquid in a filled wet leg at the high pressure side of a differential pressure transmitter
specific gravity of the liquid in a filled wet leg at the low pressure side of a differential pressure transmitter
alphanumeric character sequence identifying a wet leg filling material at the high pressure side
alphanumeric character sequence identifying a wet leg filling material at the low pressure side
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2014-12-17
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00018
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABH168
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2014-12-17
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Parameter der Differenzdruck-Füllstandmessung
- MDC_P004.en
- Parameters of differential pressure level measurement
- MDC_P006.de
- Merkmale, die eine Differenzdruckfüllstandmessung kennzeichnen
- MDC_P006.en
- properties characterizing a differential pressure level measurement
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB999,0112/2///61987#ABC005,0112/2///61987#ABC004,0112/2///61987#ABC002,0112/2///61987#ABC003,0112/2///61987#ABE885,0112/2///61987#ABC007,0112/2///61987#ABB996,0112/2///61987#ABH170,0112/2///61987#ABH169,0112/2///61987#ABH171,0112/2///61987#ABH172,0112/2///61987#ABH173,0112/2///61987#ABH174,0112/2///61987#ABB298,0112/2///61987#ABB299,0112/2///61987#ABH175,0112/2///61987#ABH176}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.