Process case variables for non-contact temperature transmitter
properties characterizing the additional operating state conditions and physical properties of a process material for non-contact temperature transmitters
Hierarchy#
Ancestors (top) → ABH229 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties7#
ratio of the radiant emittance of a substance to the radiant emittance of a black body at the same temperature
ratio of the radiant refection of a substance to the radiant reflection of a black body at the same temperature
highest duration of time between successive measurement for which a device is or has to be designed to operate within specified performance limits
mean temperature value of a material the radiation of which adds by reflection to the radiation that reaches the radiation detector
mean temperature value of a material the radiation of which adds by transmission to the radiation that reaches the radiation detector
temperature measured at a representative point within the local environment, including adjacent heat generating equipment, in which the radiation thermometer will normally operate, be stored or transported
reference to block ABH220
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00019- Dates
- Original: 2014-12-17
- Current version: 2017-09-18
- Current revision: 2017-09-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00019
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABH229
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2014-12-17
- MDC_P003_2
- 2017-09-18
- MDC_P003_3
- 2017-09-18
- MDC_P004.de
- Prozessfallgrößen für kontaktlose Temperaturmessumformer
- MDC_P004.en
- Process case variables for non-contact temperature transmitter
- MDC_P006.de
- Merkmale, die zusätzliche Betriebszustandsbedingungen und physikalischen Eigenschaften eines Prozessmediums für kontaktlose Temperaturmessumformer kennzeichnen
- MDC_P006.en
- properties characterizing the additional operating state conditions and physical properties of a process material for non-contact temperature transmitters
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABH218,0112/2///61987#ABH219,0112/2///61987#ABH313,0112/2///61987#ABH225,0112/2///61987#ABH226,0112/2///61987#ABH227,0112/2///61987#ABH228}
Version history1#