Analog input function block
properties characterizing an Analog Input function block
Hierarchy#
Ancestors (top) → ABH876 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties19#
cardinal property for the Manufacturer-specific block parameter
parameter setting the value for the second upper warning limit for the primary input
parameter setting the value for the lower warning limit for the primary input
parameter setting the value for the second lower warning limit for the primary input
parameter setting the value for the upper warning limit for the primary input
parameter determining the filter time in seconds applied to the output of an input block or input of an output block
reference to block ABH877
reference to block ABH889
reference to block ABH912
channel number or slot on which a value is made available
reference to block ABI711
reference to block ABI728
reference to block ABI757
reference to block ABI759
reference to block ABI760
reference to block ABI761
reference to block ABI762
reference to block ABI763
cardinality property for PRIMARY_MEASUREMENT
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2017-12-07
- Current version: 2019-03-08
- Current revision: 2019-03-08
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (20 keys from source .xls) — click to expand
- C002
- C00018
- C016
- Standard
- C017.de
- 0
- C018.de
- 2017-11-20
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABH876
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2019-03-08
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2019-03-08
- MDC_P003_3
- 2019-03-08
- MDC_P004.de
- Analog Input Function Block
- MDC_P004.en
- Analog input function block
- MDC_P006.de
- Merkmale, die einen Analog Input Function Block kennzeichnen
- MDC_P006.en
- properties characterizing an Analog Input function block
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABJ349,0112/2///61987#ABJ007,0112/2///61987#ABJ671,0112/2///61987#ABJ366,0112/2///61987#ABI127,0112/2///61987#ABJ395,0112/2///61987#ABI369,0112/2///61987#ABI357,0112/2///61987#ABI118,0112/2///61987#ABI121,0112/2///61987#ABI119,0112/2///61987#ABI120,0112/2///61987#ABJ397,0112/2///61987#ABJ398,0112/2///61987#ABJ399,0112/2///61987#ABJ400,0112/2///61987#ABJ401,0112/2///61987#ABI037,0112/2///61987#ABI392}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.