Control function block
properties characterizing a Control function block
Hierarchy#
Ancestors (top) → ABH885 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties26#
cardinal property for the Manufacturer-specific block parameter
parameter setting the value for the second upper warning limit for the primary input
parameter setting the value for the lower warning limit for the primary input
parameter setting the value for the second lower warning limit for the primary input
parameter setting the value for the upper warning limit for the primary input
parameter setting the dimensionless proportional value in a PID control loop
parameter setting the time allowed to balance changes in the OUT value resulting from of a change of block mode from Auto, Cas or Rcas to Man
parameter setting the derivative time in seconds in a PID control loop
parameter setting the integral time in seconds in a PID control loop
parameter setting a high limit for setpoint limiting
parameter setting a low limit for setpoint limiting
reference to block ABH877
reference to block ABH889
reference to block ABH912
channel number or slot on which a value is made available
reference to block ABI711
reference to block ABI739
reference to block ABI759
reference to block ABI760
reference to block ABI761
reference to block ABI762
reference to block ABI765
reference to block ABI816
reference to block ABI832
parameter setting the local target value for a process value
reference to block ABJ618
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2017-12-07
- Current version: 2019-03-08
- Current revision: 2019-03-08
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (20 keys from source .xls) — click to expand
- C002
- C00018
- C016
- Standard
- C017.de
- 0
- C018.de
- 2017-11-20
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABH885
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2019-03-08
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2019-03-08
- MDC_P003_3
- 2019-03-08
- MDC_P004.de
- Control Function Block
- MDC_P004.en
- Control function block
- MDC_P006.de
- Merkmale, die einen Control Function Block kennzeichnen
- MDC_P006.en
- properties characterizing a Control function block
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABJ349,0112/2///61987#ABJ007,0112/2///61987#ABJ470,0112/2///61987#ABI369,0112/2///61987#ABJ377,0112/2///61987#ABJ403,0112/2///61987#ABI143,0112/2///61987#ABI150,0112/2///61987#ABI145,0112/2///61987#ABI144,0112/2///61987#ABJ454,0112/2///61987#ABI357,0112/2///61987#ABJ710,0112/2///61987#ABJ688,0112/2///61987#ABI152,0112/2///61987#ABI153,0112/2///61987#ABI120,0112/2///61987#ABI119,0112/2///61987#ABI121,0112/2///61987#ABI118,0112/2///61987#ABJ397,0112/2///61987#ABJ398,0112/2///61987#ABJ399,0112/2///61987#ABJ400,0112/2///61987#ABI037,0112/2///61987#ABI392}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.