Skip to content
OpenCDD
classITEM_CLASSv1rev 12019-03-08

Standard parameters

0112/2///61987#ABI711

properties characterizing a set of parameters to be found in every function and technology block type

Hierarchy#

Ancestors (top) → ABI711 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties12#

12 / 12
ABB271tag nameNON_TRANSLATABLE_STRING_TYPE

alphanumeric character sequence uniquely identifying a measuring or control point

ABI580ALERT_KEYINT_TYPE

user assigned value which may be used in sorting alarms or events generated by a block

ABI649BLOCK_ERRORNON_TRANSLATABLE_STRING_TYPE

parameter indicating the type of error that is present in a block

ABI971STATIC_REVISIONINT_TYPE

parameter indicating the number of changes to static parameters made in the block

ABI972STRATEGYINT_TYPE

user-specified value to be used in configuration or diagnostics as a key in sorting block information.

ABJ721ALARM_DELAYREAL_TYPE

parameter, setting the time in seconds an alarm is delayed

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
1
Revision
1
Status
Standard
Responsible committee
SC65E – IEC 61987
Change request
C00018
Dates
  • Original: 2017-12-07
  • Current version: 2019-03-08
  • Current revision: 2019-03-08

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (20 keys from source .xls) — click to expand
C002
C00018
C016
Standard
C017.de
0
C018.de
2017-11-20
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABI711
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2019-03-08
MDC_P003_1
2017-12-07
MDC_P003_2
2019-03-08
MDC_P003_3
2019-03-08
MDC_P004.de
Standard-Parameter
MDC_P004.en
Standard parameters
MDC_P006.de
Merkmale, die einen Parametersatz kennzeichnen, der in jedem Function und Technology Block verwendet wird
MDC_P006.en
properties characterizing a set of parameters to be found in every function and technology block type
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABI971,0112/2///61987#ABB271,0112/2///61987#ABI972,0112/2///61987#ABI580,0112/2///61987#ABJ352,0112/2///61987#ABI649,0112/2///61987#ABJ353,0112/2///61987#ABJ721,0112/2///61987#ABJ434,0112/2///61987#ABJ722,0112/2///61987#ABJ723,0112/2///61987#ABJ435}

Version history1#

  1. Current rev 01
    08 Mar 2019 · 15:35 UTC by BATCH 00000766
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.