On-off actuation technology block
properties characterizing an On-off actuation technology block
Hierarchy#
Ancestors (top) → ABI752 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties16#
cardinal property for the Manufacturer-specific block parameter
reference to block ABH912
parameter indicating the fail-safe action of the actuator on power-loss
parameter indication the result of the device-specific calibration-procedure
parameter indicating the sum of cycles from OPEN to CLOSE and CLOSE to OPEN
parameter indicating the limit for TRAVEL_COUNT
parameter indicating the time in ms between the command to change of the state from CLOSE position and the indication that the actuator starts its action
parameter indicating the time in ms between the command to change of the state from OPEN position and the indication that the actuator starts its action
parameter indicating the time in s between the command to change of the state from CLOSE position and the indication that the actuator has finished its action
parameter indicating the time in s between the command to change of the state from OPEN position and the indication that the actuator has finished its action
reference to block ABI711
reference to block ABI734
reference to block ABI735
parameter indicating the demand to the discrete actuator resulting from the transformation function
parameter indicating the result feedback from the, actuation acquisition function
parameter initializing a test procedure to check the sensor or actuator
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2017-12-07
- Current version: 2019-03-08
- Current revision: 2019-03-08
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (20 keys from source .xls) — click to expand
- C002
- C00018
- C016
- Standard
- C017.de
- 0
- C018.de
- 2017-11-20
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABI752
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2019-03-08
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2019-03-08
- MDC_P003_3
- 2019-03-08
- MDC_P004.de
- On-off Actuation Technology Block
- MDC_P004.en
- On-off actuation technology block
- MDC_P006.de
- Merkmale, die einen On-off Actuation Technology Block kennzeichnen
- MDC_P006.en
- properties characterizing an On-off actuation technology block
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABJ349,0112/2///61987#ABJ372,0112/2///61987#ABJ634,0112/2///61987#ABJ635,0112/2///61987#ABJ373,0112/2///61987#ABI603,0112/2///61987#ABI990,0112/2///61987#ABI991,0112/2///61987#ABI992,0112/2///61987#ABI993,0112/2///61987#ABI999,0112/2///61987#ABJ000,0112/2///61987#ABI606,0112/2///61987#ABJ660,0112/2///61987#ABI037,0112/2///61987#ABI392}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.