Modulation actuation technology block
properties characterizing a Modulation actuation technology block
Hierarchy#
Ancestors (top) → ABI812 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties16#
parameter selecting the type of linearization
cardinal property for the Manufacturer-specific block parameter
reference to block ABH912
parameter indicating the fail-safe action of the actuator on power-loss
parameter indication the result of the device-specific calibration-procedure
parameter indicating the minimum time in seconds required to move from OPEN to CLOSE position
parameter indicating the minimum time in seconds required to move from CLOSE to OPEN position
parameter setting the deadband in percent of travel span
parameter in percentage of setpoint span below which the actuator signal goes to the minimum limit
parameter in percentage of setpoint span above which the actuator signal goes to the maximum limit
reference to block ABI711
reference to block ABI738
parameter indicating the demand to the actuator resulting from the transformation function
parameter initializing a test procedure to check the sensor or actuator
parameter indicating the result feedback from the actuation acquisition function
reference to block ABJ618
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2017-12-07
- Current version: 2019-03-08
- Current revision: 2019-03-08
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (20 keys from source .xls) — click to expand
- C002
- C00018
- C016
- Standard
- C017.de
- 0
- C018.de
- 2017-11-20
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABI812
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2019-03-08
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2019-03-08
- MDC_P003_3
- 2019-03-08
- MDC_P004.de
- Modulation Actuation Technology Block
- MDC_P004.en
- Modulation actuation technology block
- MDC_P006.de
- Merkmale, die einen Modulation Actuation Technology Block kennzeichnen
- MDC_P006.en
- properties characterizing a Modulation actuation technology block
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABJ349,0112/2///61987#ABJ376,0112/2///61987#ABJ631,0112/2///61987#ABJ682,0112/2///61987#ABJ710,0112/2///61987#ABI603,0112/2///61987#ABJ121,0112/2///61987#ABJ131,0112/2///61987#ABJ132,0112/2///61987#ABJ113,0112/2///61987#ABJ114,0112/2///61987#ABH945,0112/2///61987#ABI606,0112/2///61987#ABJ660,0112/2///61987#ABI037,0112/2///61987#ABI392}