FLOW_MEASUREMENT_TRANSFORMATION
properties characterizing any transformations to the flow technology block output value
Hierarchy#
Ancestors (top) → ABJ612 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties4#
parameter setting the value at which the output of the flow function is set to zero
parameter enabling or disabling the empty pipe detection function
parameter defined in manufacturer specific tables setting the degree of damping on the block output
parameter defined in manufacturer specific tables setting the type of linearization e.g. none, square-root, polynomial or tabular
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Note
- These modifications directly affect the value of the primary measurement.
- Version
- 1
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00018- Dates
- Original: 2017-12-07
- Current version: 2019-03-08
- Current revision: 2019-03-08
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00018
- C016
- Standard
- C017.de
- 0
- C018.de
- 2017-11-20
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABJ612
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2019-03-08
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2019-03-08
- MDC_P003_3
- 2019-03-08
- MDC_P004.de
- FLOW_MEASUREMENT_TRANSFORMATION
- MDC_P004.en
- FLOW_MEASUREMENT_TRANSFORMATION
- MDC_P006.de
- Merkmale, die alle Transformationen zum Technology Block-Ausgangswert des Durchfluss-Technology Blocks kennzeichnen
- MDC_P006.en
- properties characterizing any transformations to the flow technology block output value
- MDC_P008.de
- Diese Modifikationen beeinflussen direkt den PRIMARY_MEASUREMENT_VALUE
- MDC_P008.en
- These modifications directly affect the value of the primary measurement.
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABJ679,0112/2///61987#ABJ629,0112/2///61987#ABI105,0112/2///61987#ABJ659}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.