Continuous measurement variables
properties characterizing dynamic data which are the result of a measurement and where two values could have an infinite small difference
Hierarchy#
Ancestors (top) → ABN682 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties31#
scalar or tensor quantity the product of which by the electric field strength in a medium is equal to the electric current density
for a physical system exchanging quantities of heat with two bodies, during a reversible cycle, a positive state quantity characterizing each body and proportional to the quantity of heat exchanged with this body
rate of propagation of an acoustic wave
measure for the friction forces of fluids
rate of heat flow per unit temperature and unit length
mass of material flowing per unit time
measure for the friction forces of a fluid divided by the fluid density
number of revolutions per time
material characteristic expressed as the capacitance between two plates when the intervening space is filled with a given insulating material and the capacitance of the same plate arrangement when the space is filled with air or is evacuated
height of process material in a tank, vessel, silo or other container
at a point of a surface, scalar quantity equal to the limit of the quotient of the magnitude of the component vector normal to the surface of the force acting at this point, by the area of a surface containing the point, when all the dimensions of that surface tend to zero
reciprocal of the period
derivative with respect to time t of energy E being transferred or transformed
one-dimensional subspace of space-time, which is locally orthogonal to space
quantity equal to the volume dV of substance crossing a given surface during a time interval with infinitesimal duration dt, divided by this duration, thus qV = dV / dt
result of an addition or of successive additions of values of variables
at a given point within a three-dimensional domain of quasi-infinitesimal volume dV, scalar quantity equal to the mass dm within the domain divided by the volume dV, thus ρ = dm/dV
one-dimensional subspace of space-time, which is locally orthogonal to time
ABN741reference to Specific pressure measurement variablesCLASS_REFERENCE_TYPE(0112/2///61987#ABN683)reference to block ABN683
ABN742reference to Specific flow rate measurement variablesCLASS_REFERENCE_TYPE(0112/2///61987#ABN684)reference to block ABN684
ABN743reference to Specific totalizer value measurement variablesCLASS_REFERENCE_TYPE(0112/2///61987#ABN685)reference to block ABN685
reference to block ABN686
ABN745reference to Specific density measurement variablesCLASS_REFERENCE_TYPE(0112/2///61987#ABN687)reference to block ABN687
reference to block ABN688
reference to block ABN689
ABN748reference to Specific environmental measurement variablesCLASS_REFERENCE_TYPE(0112/2///61987#ABN690)reference to block ABN690
ABN749reference to Specific electrical measurement variablesCLASS_REFERENCE_TYPE(0112/2///61987#ABN691)reference to block ABN691
reference to block ABN692
reference to block ABN693
ABN752reference to Specific machine vibration measurement variablesCLASS_REFERENCE_TYPE(0112/2///61987#ABN694)reference to block ABN694
ABN753reference to Specific final control elements diagnostic variablesCLASS_REFERENCE_TYPE(0112/2///61987#ABN695)reference to block ABN695
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00092- Dates
- Current version: 2020-02-24
- Current revision: 2020-02-24
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (19 keys from source .xls) — click to expand
- C002
- C00092
- C016
- Standard
- C017.de
- 0
- C018.de
- 19-08-16
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABN682
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2020-02-24
- MDC_P003_2
- 2020-02-24
- MDC_P003_3
- 2020-02-24
- MDC_P004.de
- Kontinuierliche Messgrößen
- MDC_P004.en
- Continuous measurement variables
- MDC_P006.de
- Merkmale, die dynamische Daten, die das Ergebnis einer Messung sind, kennzeichnen, bei denen die Differenz zweier Werte unendlich klein sein kann
- MDC_P006.en
- properties characterizing dynamic data which are the result of a measurement and where two values could have an infinite small difference
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABA927,0112/2///61987#ABN616,0112/2///61987#ABN741,0112/2///61987#ABB290,0112/2///61987#ABN698,0112/2///61987#ABN742,0112/2///61987#ABN699,0112/2///61987#ABN743,0112/2///61987#ABH329,0112/2///61987#ABN744,0112/2///61987#ABN700,0112/2///61987#ABN745,0112/2///61987#ABB067,0112/2///61987#ABB300,0112/2///61987#ABA560,0112/2///61987#ABB094,0112/2///61987#ABB066,0112/2///61987#ABH062,0112/2///61987#ABN746,0112/2///61987#ABN747,0112/2///61987#ABN748,0112/2///61987#ABN624,0112/2///61987#ABF194,0112/2///61987#ABN625,0112/2///61987#ABN749,0112/2///61987#ABN626,0112/2///61987#ABN750,0112/2///61987#ABN718,0112/2///61987#ABN751,0112/2///61987#ABN752,0112/2///61987#ABN753}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.