Absolute performance for apparent power [I/O module]
properties characterizing the accuracy of an apparent power measurement of an I/O module, expressed in engineering units
Hierarchy#
Ancestors (top) → ABP005 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties10#
equation from which the measured error of a device can be calculated
equation from which the non-repeatability of a device can be calculated
reference to block ABC210
probability, generally expressed as a percentage, that the true value of a statistically estimated quantity falls within a pre-established interval about the estimated value
quality which characterizes the ability of an apparent power measuring instrument to provide an indicated value close to a true value of the measurand under reference conditions
for an apparent power measurement, maximum positive and negative deviation from the specified characteristic curve observed in testing a device under specified conditions and by a specified procedure
largest positive or negative value of error of the average upscale or downscale value at each point of apparent power measurement expressed as an absolute value
algebraic difference between the extreme values obtained by a number of consecutive measurements of the output over a short period of time for the same value of the input under the same operating conditions, approaching from the same direction, for full range traverses of apparent power
absolute error of a device measuring apparent power under reference conditions, when the input is at the lower range value
ABP240ref. Influence of external quantities expressed for apparent power [I/O module]CLASS_REFERENCE_TYPE(0112/2///61987#ABP036)reference to block ABP036
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00128- Dates
- Original: 2023-01-23
- Current version: 2023-01-23
- Current revision: 2023-01-23
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00128
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2021-11-23
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABP005
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2023-01-23
- MDC_P003_1
- 2023-01-23
- MDC_P003_2
- 2023-01-23
- MDC_P003_3
- 2023-01-23
- MDC_P004.de
- Leistungsdaten für Scheinleistung in absoluten Einheiten [I/O-Modul]
- MDC_P004.en
- Absolute performance for apparent power [I/O module]
- MDC_P006.de
- Merkmale, die die Genauigkeit einer Scheinleistungsmessung eines I/O-Moduls, ausgedrückt in physikalischen Einheiten, kennzeichnen
- MDC_P006.en
- properties characterizing the accuracy of an apparent power measurement of an I/O module, expressed in engineering units
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABP092,0112/2///61987#ABD535,0112/2///61987#ABP144,0112/2///61987#ABP109,0112/2///61987#ABP183,0112/2///61987#ABP158,0112/2///61987#ABB519,0112/2///61987#ABB774,0112/2///61987#ABP240,0112/2///61987#ABC840}
- MDC_P019
- false
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.