Absolute performance for other variable [I/O module]

0112/2///61987#ABP007

properties characterizing the accuracy of an other variable measurement of an I/O module, expressed in engineering units

Hierarchy#

Ancestors (top) → ABP007 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties12#

12 / 12

largest positive or negative value of error of the average upscale or downscale value at each point of other variable measurement expressed as an absolute value

quality which characterizes the ability of another variable measuring instrument to provide an indicated value close to a true value of the measurand under reference conditions

for another variable measurement, the maximum positive and negative deviation from the specified characteristic curve observed in testing a device under specified conditions and by a specified procedure

absolute error of a device measuring another variable under reference conditions, when the input is at the lower range value

algebraic difference between the extreme values obtained by a number of consecutive measurements of the output over a short period of time for the same value of the input under the same operating conditions, approaching from the same direction, for full range traverses of another variable

ABD535confidence levelENUM_STRING_TYPE

probability, generally expressed as a percentage, that the true value of a statistically estimated quantity falls within a pre-established interval about the estimated value

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
1
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
IEC/SC 65E
Change request
C00128
Dates
  • Original: 2023-01-23
  • Current version: 2023-01-23
  • Current revision: 2023-01-23

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (23 keys from source .xls) — click to expand
C002
C00128
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C018.de
2021-11-23
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABP007
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2023-01-23
MDC_P003_1
2023-01-23
MDC_P003_2
2023-01-23
MDC_P003_3
2023-01-23
MDC_P004.de
Leistungsdaten für weitere Messgröße in absoluten Einheiten [I/O-Modul]
MDC_P004.en
Absolute performance for other variable [I/O module]
MDC_P006.de
Merkmale, die die Genauigkeit einer weiteren Messgrößenmessung eines I/O-Moduls, ausgedrückt in physikalischen Einheiten, kennzeichnen
MDC_P006.en
properties characterizing the accuracy of an other variable measurement of an I/O module, expressed in engineering units
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
IEC/SC 65E
MDC_P014
{0112/2///61987#ABB198,0112/2///61987#ABB791,0112/2///61987#ABD535,0112/2///61987#ABB788,0112/2///61987#ABB792,0112/2///61987#ABB793,0112/2///61987#ABB794,0112/2///61987#ABB787,0112/2///61987#ABB519,0112/2///61987#ABB774,0112/2///61987#ABP242,0112/2///61987#ABC840}