Tuneable diode laser spectrometer-specific condition monitoring variables
properties characterizing dynamic data which are diagnostic results generated for a tuneable diode laser spectrometer
Hierarchy#
Ancestors (top) → ABP489 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties6#
absolute pressure of sample gas inside a detection system
temperature of the sample at the point of measurement
degree of correlation between the calculated and the measured absorption signal
linear ratio of the signal level to the noise level as measured under specified conditions
ratio of the value of a specified radiation quantity in the centre of a beam of specified radiation quality and under specified geometrical conditions after passage through a material to the value which would be present at the same position without this material in the beam
measured temperature of the element that defines the wavelength of a laser
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00172- Dates
- Original: 2025-02-24
- Current version: 2025-02-24
- Current revision: 2025-02-24
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00172
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2023-03-06
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABP489
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2025-02-24
- MDC_P003_1
- 2025-02-24
- MDC_P003_2
- 2025-02-24
- MDC_P003_3
- 2025-02-24
- MDC_P004.de
- Condition Monitoring-Variablen für Diodenlaserspektrometer
- MDC_P004.en
- Tuneable diode laser spectrometer-specific condition monitoring variables
- MDC_P006.de
- Merkmale, die dynamische Daten charakterisieren, bei denen es sich um Diagnosedaten handelt, welche für einen Diodenlaserspektrometer erzeugt wurden
- MDC_P006.en
- properties characterizing dynamic data which are diagnostic results generated for a tuneable diode laser spectrometer
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABP580,0112/2///61987#ABP581,0112/2///61987#ABP582,0112/2///61987#ABP583,0112/2///61987#ABP575,0112/2///61987#ABP560}
- MDC_P019
- false
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.