Zirconium dioxide analyser-specific condition monitoring variables
properties characterizing dynamic data which are diagnostic results generated for a zirconium dioxide analyser
Hierarchy#
Ancestors (top) → ABP490 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties5#
volume flow of a sample gas through a detection system
temperature measured at a sensing element
degradation of a sensing element expressed as a value between 1 (good) and 0 (bad)
relative heat output referred to the maximum heat output to keep the sensor at its setpoint temperature during operation
ratio of the electrical voltage to the electrical current flowing through a sensing element
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00172- Dates
- Original: 2025-02-24
- Current version: 2025-02-24
- Current revision: 2025-02-24
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00172
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2023-03-06
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABP490
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2025-02-24
- MDC_P003_1
- 2025-02-24
- MDC_P003_2
- 2025-02-24
- MDC_P003_3
- 2025-02-24
- MDC_P004.de
- Condition Monitoring-Variablen für Zirkondioxid-Analysator
- MDC_P004.en
- Zirconium dioxide analyser-specific condition monitoring variables
- MDC_P006.de
- Merkmale, die dynamische Daten charakterisieren, bei denen es sich um Diagnosedaten handelt, welche für einen Zirkondioxid-Analysator erzeugt wurden
- MDC_P006.en
- properties characterizing dynamic data which are diagnostic results generated for a zirconium dioxide analyser
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABP584,0112/2///61987#ABP585,0112/2///61987#ABP596,0112/2///61987#ABP565,0112/2///61987#ABP562}
- MDC_P019
- false
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.