Measured variable [process analyser]
properties characterizing a measured variable, the size of which is to be acquired and indicated by the device
Hierarchy#
Ancestors (top) → ABP911 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties12#
alphanumeric character sequence identifying the category and function of a process control engineering request
alphanumeric character sequence uniquely identifying a measuring or control point
reference to block ABC079
reference to block ABC528
ABP965reference to Mass concentration (per volume) measurementCLASS_REFERENCE_TYPE(0112/2///61987#ABP912)reference to block ABP912
ABP966reference to Volume concentration (per volume) measurementCLASS_REFERENCE_TYPE(0112/2///61987#ABP913)reference to block ABP913
reference to block ABP914
reference to block ABP915
reference to block ABP916
ABP970reference to Spectral linear absorption coefficient (SAC) measurementCLASS_REFERENCE_TYPE(0112/2///61987#ABP917)reference to block ABP917
ABP971reference to Percentage turbidity (total solids) measurementCLASS_REFERENCE_TYPE(0112/2///61987#ABP918)reference to block ABP918
ABP972reference to Percentage turbidity (suspended solids) measurementCLASS_REFERENCE_TYPE(0112/2///61987#ABP919)reference to block ABP919
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00172- Dates
- Original: 2025-02-24
- Current version: 2025-02-24
- Current revision: 2025-02-24
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00172
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2023-12-11
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABP911
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2025-02-24
- MDC_P003_1
- 2025-02-24
- MDC_P003_2
- 2025-02-24
- MDC_P003_3
- 2025-02-24
- MDC_P004.de
- Messgröße [Prozessanalysengerät]
- MDC_P004.en
- Measured variable [process analyser]
- MDC_P006.de
- Merkmale, die eine Messgröße kennzeichnen, deren Wert vom Gerät ermittelt und angezeigt werden soll
- MDC_P006.en
- properties characterizing a measured variable, the size of which is to be acquired and indicated by the device
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABB271,0112/2///61987#ABA577,0112/2///61987#ABP965,0112/2///61987#ABP966,0112/2///61987#ABP967,0112/2///61987#ABP968,0112/2///61987#ABP969,0112/2///61987#ABP970,0112/2///61987#ABP971,0112/2///61987#ABP972,0112/2///61987#ABD158,0112/2///61987#ABC709}
- MDC_P019
- false
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.