Infrared sensor-specific condition monitoring variables
properties characterizing dynamic data which are diagnostic results generated for an infrared sensor
Hierarchy#
Ancestors (top) → ABP997 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties14#
point in time when a measurement channel of a device was calibrated
temperature measured at a sensing element
ratio of the value of a specified radiation quantity in the centre of a beam of specified radiation quality and under specified geometrical conditions after passage through a material to the value which would be present at the same position without this material in the beam
degradation of a sensing element expressed as a value between 1 (good) and 0 (bad)
summed duration of time intervals for which the sensor was in an operating powered state
flow rate of gas expressed as a value between 100 (good) and 0 (bad)
concentration of the reference gas applied at the upper setpoint of calibration
concentration of the reference gas applied at the lower setpoint of calibration
ABQ014actual value of gas concentration at upper calibration point before adjustmentREAL_MEASURE_TYPEmeasured value of gas concentration at the upper setpoint for calibration before calibrating
ABQ015actual value of gas concentration at lower calibration point before adjustmentREAL_MEASURE_TYPEmeasured value of gas concentration at the lower setpoint for calibration before calibrating
time expressed in days that can elapse until the next calibration, calculated from the configured calibration interval
ABQ017days remaining until next calibration (based on dynamic maintenance interval)REAL_MEASURE_TYPEtime expressed in days that can elapse until the next calibration, estimated from operational or historical information
degradation of a sensing element expressed as a value between 1 (good) and 0 (bad) calculated during its calibration
degradation of an infrared radiation source expressed as a value between 1 (good) and 0 (bad)
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00172- Dates
- Original: 2025-02-24
- Current version: 2025-02-24
- Current revision: 2025-02-24
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00172
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2024-06-14
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABP997
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2025-02-24
- MDC_P003_1
- 2025-02-24
- MDC_P003_2
- 2025-02-24
- MDC_P003_3
- 2025-02-24
- MDC_P004.de
- Condition Monitoring-Variablen für Infrarot-Sensor
- MDC_P004.en
- Infrared sensor-specific condition monitoring variables
- MDC_P006.de
- Merkmale, die dynamische Daten charakterisieren, bei denen es sich um Diagnosedaten handelt, welche für einen Infrarot-Sensor erzeugt wurden
- MDC_P006.en
- properties characterizing dynamic data which are diagnostic results generated for an infrared sensor
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABQ010,0112/2///61987#ABP565,0112/2///61987#ABP584,0112/2///61987#ABQ011,0112/2///61987#ABP544,0112/2///61987#ABQ012,0112/2///61987#ABQ013,0112/2///61987#ABQ014,0112/2///61987#ABQ015,0112/2///61987#ABQ016,0112/2///61987#ABQ017,0112/2///61987#ABQ040,0112/2///61987#ABQ041,0112/2///61987#ABP582}
- MDC_P019
- false
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.