Substance

0112/2///61987#ABQ001

properties characterizing the substance injected into the GC

Hierarchy#

ABA000 Equipment for industr… ABV001 Libraries ABV501 Block ABQ001 Substance ABQ001 Substance

Ancestors (top) → ABQ001 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties16#

16 / 16
ABQ023peak height of a substanceREAL_MEASURE_TYPE

magnitude of a Process GC output signal in units defined by the manufacturer, measured from the peak tip perpendicular to the baseline

ratio between the concentration of a compound being analysed and the response of the detector to that compound for the calibration range 1

ratio between the concentration of a compound being analysed and the response of the detector to that compound for the calibration range 2

ratio between the concentration of a compound being analysed and the response of the detector to that compound for the calibration range 3

ABQ033tailing factorREAL_MEASURE_TYPE

asymmetry of a substance peak in a chromatogram expressed as the ratio of the back part to the front part of the peak, referred to the peak maximum, at 10 % peak height above the baseline

integral of the area under the output peak of a chromatogram signal in units defined by the manufacturer

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
1
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
IEC/SC 65E
Change request
C00172
Dates
  • Original: 2025-02-24
  • Current version: 2025-02-24
  • Current revision: 2025-02-24

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (23 keys from source .xls) — click to expand
C002
C00172
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C018.de
2024-06-14
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABQ001
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2025-02-24
MDC_P003_1
2025-02-24
MDC_P003_2
2025-02-24
MDC_P003_3
2025-02-24
MDC_P004.de
Substanz
MDC_P004.en
Substance
MDC_P006.de
Merkmale, die Substanz kennzeichnen, die in den GC injiziert wird
MDC_P006.en
properties characterizing the substance injected into the GC
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
IEC/SC 65E
MDC_P014
{0112/2///61987#ABQ045,0112/2///61987#ABQ022,0112/2///61987#ABQ023,0112/2///61987#ABQ042,0112/2///61987#ABQ024,0112/2///61987#ABQ025,0112/2///61987#ABQ026,0112/2///61987#ABQ027,0112/2///61987#ABQ028,0112/2///61987#ABQ029,0112/2///61987#ABQ030,0112/2///61987#ABQ031,0112/2///61987#ABQ032,0112/2///61987#ABQ033,0112/2///61987#ABQ034,0112/2///61987#ABQ035}
MDC_P019
false