Reference device conditions [7]
properties characterizing the reference conditions of the device under which the performance of a device was tested
Hierarchy#
Ancestors (top) → ABU697 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties13#
standard on which a stated accuracy value is based
standard on which a stated accuracy value is based
device orientation at which the performance of a device was tested
warm-up time of the device after which the performance of a device was tested
supply voltage with which the performance of a device was tested
output load at which the performance of a device was tested
turndown of the device output at which the performance of a device was tested
@number of further reference conditions
reference to block ABC259
value of the signal response time with which the performance of a device was tested
value of the confidence level with which the performance of a device was tested
value of the temperature of device with which the performance of a device was tested
value of the measuring time with which the performance of a device was tested
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Remark
- Id specified in IEC61987: ABG242
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00017- Dates
- Original: 2014-12-17
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (28 keys from source .xls) — click to expand
- C002
- C00017
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-17
- C018.fr
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- C019.fr
- UTE
- MDC_P001_5
- 0112/2///61987#ABU697
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2014-12-17
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Referenz-Gerätebedingungen
- MDC_P004.en
- Reference device conditions [7]
- MDC_P004.fr
- Conditions d’appareil de référence
- MDC_P006.de
- Merkmale, die die Referenzgrößen des Geräts kennzeichnen, bei denen die Leistung des Geräts bestimmt wurde
- MDC_P006.en
- properties characterizing the reference conditions of the device under which the performance of a device was tested
- MDC_P006.fr
- propriétés caractérisant les conditions de référence de l’appareil dans lesquelles les performances d’un appareil sont soumises à essai
- MDC_P009.en
- Id specified in IEC61987: ABG242
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB646,0112/2///61987#ABB647,0112/2///61987#ABB649,0112/2///61987#ABB650,0112/2///61987#ABB651,0112/2///61987#ABF303,0112/2///61987#ABF304,0112/2///61987#ABF305,0112/2///61987#ABF306,0112/2///61987#ABB799,0112/2///61987#ABC889,0112/2///61987#ABB278,0112/2///61987#ABB278}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.