Skip to content
OpenCDD
classITEM_CLASSv1rev 12016-05-24

Design ratings for thermowell

0112/2///61987#ABV238

properties characterizing the limiting conditions for avoiding mechanical damage of a thermowell

Hierarchy#

Ancestors (top) → ABV238 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties5#

ABA114maximum fluid velocityREAL_MEASURE_TYPE

highest fluid velocity for which a device is or should be designed to operate within its specified limits

ABF559maximum dynamic pressureREAL_MEASURE_TYPE

highest dynamic pressure for which a device is or must be designed to operate within its specified limits

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Note
The calculation is based on the reference parameters by means of the corresponding thermowell standard.
Remark
Id specified in IEC61987: ABF554
Version
1
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
SC65E – IEC 61987
Change request
C00019
Dates
  • Original: 2014-12-17
  • Current version: 2016-05-24
  • Current revision: 2016-05-24

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (25 keys from source .xls) — click to expand
C002
C00019
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C018.de
2014-12-17
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABV238
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2018-03-28
MDC_P003_1
2014-12-17
MDC_P003_2
2016-05-24
MDC_P003_3
2016-05-24
MDC_P004.de
Auslegungsdaten für Thermometer-Schutzrohr
MDC_P004.en
Design ratings for thermowell
MDC_P006.de
Merkmale, die die Grenzbedingungen zur Vermeidung von mechanischen Schäden eines Thermometer-Schutzrohrs kennzeichnen
MDC_P006.en
properties characterizing the limiting conditions for avoiding mechanical damage of a thermowell
MDC_P008.de
Die Berechnung basiert auf den Referenzparametern mittels entsprechender Thermometer-Schutzrohrstandards.
MDC_P008.en
The calculation is based on the reference parameters by means of the corresponding thermowell standard.
MDC_P009.en
Id specified in IEC61987: ABF554
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABF556,0112/2///61987#ABF557,0112/2///61987#ABF558,0112/2///61987#ABF559,0112/2///61987#ABA114}

Version history1#

  1. Current rev 01
    28 Mar 2018 · 07:26 UTC by BATCH 00000762
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.