Front element for emergency stop push-button
actuator of the switching device intended to be operated by force exerted by a part of the human body in emergency situations, usually the finger or palm of the hand, and having stored energy (spring) return
Hierarchy#
Ancestors (top) → ACC527 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties5#
information necessary for unambiguous identification of the device
physical information of the device for installation
ACF158Head of the control circuit device for Emergency stop push-buttonCLASS_REFERENCE_TYPE(0112/2///62683#ACG158)part which contains and support the actuator or contains the lens of an indicator light, fixed on an enclosure or on the body of the emergency stop push-button
ACF179General technical data for Front element for emergency stop push-buttonCLASS_REFERENCE_TYPE(0112/2///62683#ACG179)general technical aspects of the front element for emergency stop push-button
conformity of a device with specified requirements and compliance with recognised product standards
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Source document
- derived from IEC 60947-5-5/AM2:2016, 3.3
- Version
- 1
- Revision
- 3
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 62683-1:2017
- Responsible committee
- IEC SC121A
- Change request
C00146- Dates
- Original: 2012-12-14
- Current version: 2016-09-16
- Current revision: 2020-01-11
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (34 keys from source .xls) — click to expand
- C002
- C00146
- C011
- IEC
- C012
- IEC 62683-1:2017
- C016
- Standard
- C017.de
- 1
- C017.fr
- 2
- C017.zh
- 1
- C018.de
- 2017-06-15
- C018.fr
- 2025-03-14
- C018.zh
- 2017-09-26
- C019.de
- DKE, Jürgen Schütz
- C019.fr
- AFNOR
- C019.zh
- SAC, Li Hui
- MDC_P001_5
- 0112/2///62683#ACC527
- MDC_P002_1
- 1
- MDC_P002_2
- 3
- MDC_P003_0
- 2020-01-11
- MDC_P003_1
- 2012-12-14
- MDC_P003_2
- 2016-09-16
- MDC_P003_3
- 2020-01-11
- MDC_P004.de
- Frontelement für einen NOT-HALT-Drucktaster
- MDC_P004.en
- Front element for emergency stop push-button
- MDC_P004.fr
- Unité frontale du bouton d'arrêt d'urgence
- MDC_P004.zh
- 紧急制动按钮前部操动元件
- MDC_P006_1
- derived from IEC 60947-5-5/AM2:2016, 3.3
- MDC_P006.de
- Bedienteil eines Schaltgeräts mit Kraftspeicherrückstellung (Feder) das durch von Menschen im Allgemeinen mit den Fingern oder den Handflächen ausgeführten Schub betätigt wird
- MDC_P006.en
- actuator of the switching device intended to be operated by force exerted by a part of the human body in emergency situations, usually the finger or palm of the hand, and having stored energy (spring) return
- MDC_P006.fr
- organe de commande de l'appareil de connexion destiné à être actionné par l'effort exercé par une partie du corps humain en situation d'urgence, généralement le doigt ou la paume de la main, et possédant une énergie de rappel accumulée (ressort)
- MDC_P006.zh
- 具有在紧急情况下用人体的一部分(一般为用手指或手掌)施加力而操作操动器并具有储能(弹簧)复位的开关设备控制器。
- MDC_P010
- 0112/2///62683#ACC500
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC SC121A
- MDC_P014
- {0112/2///62683#ACF001,0112/2///62683#ACF179,0112/2///62683#ACF158,0112/2///62683#ACF146,0112/2///62683#ACF701}
- MDC_P019
- true
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.