Skip to content
OpenCDD
classITEM_CLASSv1rev 12020-01-11

Connection facilities

0112/2///62683#ACG250

terminals, screws or other parts, used for the electrical connection of conductors of external circuits of the foot switch

Inherited
32

Hierarchy#

Ancestors (top) → ACG250 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties#

No declared properties

This class does not declare any properties of its own.

Inherited properties (32) — click to expand
ACE850clamping unitENUM_STRING_TYPE

the part(s) of the terminal necessary for the mechanical clamping and the electrical connection of the conductor(s), including the parts which are necessary to ensure the correct contact pressure

ACE876size of cable entriesENUM_STRING_TYPE

mechanical characteristic of the opening in the housing necessary for the electrical connection

ACE851clamping unit, second typeENUM_STRING_TYPE

the part(s) of the terminal necessary for the mechanical clamping and the electrical connection of the conductor(s), including the parts which are necessary to ensure the correct contact pressure, second type integrated in the device

ACE852clamping unit of main circuitENUM_STRING_TYPE

type of electrical connection of the main circuit of a device to the conductor suitable for the intended use

ACE855disconnecting methodENUM_STRING_TYPE

construction type enabling the device to be disconnected from the main circuit or to be removed

physical design of the electrical connection from the body of the sensor to the conductor suitable for the intended use

ACE857cable lengthREAL_MEASURE_TYPE

value of the length of the electrical connecting cable

ACE858plug-in unitENUM_BOOLEAN_TYPE

unit which plugs into a rack and is supported by guides

ACE861cross-section in AWG or kcmil sizeENUM_CODE_TYPE(0112/2///61987#ABN524)

maximum cross-section expressed in AWG or kcmil size of all connectable types of conductors, rigid (solid and stranded) and flexible, stated by the manufacturer, and to which certain thermal, mechanical and electrical requirements are referred

ACE862rated cross-sectionREAL_MEASURE_TYPE

value of the maximum cross-section of all connectable types of conductors, rigid (solid and stranded) and flexible, stated by the manufacturer, and to which certain thermal, mechanical and electrical requirements are referred

ACE865cross-section of flexible conductorLEVEL(MIN,MAX) OF REAL_MEASURE_TYPE

range of the cross-sections of connectable flexible conductors, stated by the manufacturer, and to which some mechanical and electrical requirements are referred by the performed tests

ACE867cross-section of rigid conductorLEVEL(MIN,MAX) OF REAL_MEASURE_TYPE

range of the cross-sections of connectable rigid conductors, stated by the manufacturer, and to which some mechanical and electrical requirements are referred by the performed tests

ACE869connection orientationENUM_STRING_TYPE

orientation of the wire connection compared to the mounting surface of the device

ACF095conductor entry reference pointCLASS_REFERENCE_TYPE(0112/2///62683#ACG095)

point of reference located at the extreme left (x axis), bottom (z axis) and rear (z axis) of the conductor entry

ACE894conductor entry positionENUM_STRING_TYPE

relative location of the part with openings which permit the passage of conductors into the assembly

ACE895conductor entry depthINTEGER_MEASURE_TYPE

dimension of the conductor entry from its reference point along axis "Z”

ACE896conductor entry heightINTEGER_MEASURE_TYPE

dimension of the conductor entry from its reference point along its axis "Y”

ACE897conductor entry shapeENUM_STRING_TYPE

geometry of the of the part with openings which permit the passage of conductors into the assembly

ACE898conductor entry widthINTEGER_MEASURE_TYPE

dimension of the conductor entry from its reference point along its axis "X”

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Is case of (powertype parents)1#

Metadata#

Version
1
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 62683DB
Responsible committee
IEC SC121A
Change request
C00073
Dates
  • Original: 2016-02-01
  • Current version: 2020-01-11
  • Current revision: 2020-01-11

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (33 keys from source .xls) — click to expand
C002
C00073
C011
IEC
C012
IEC 62683DB
C016
Standard
C017.de
1
C017.fr
1
C017.zh
1
C018.de
2017-12-05
C018.fr
2020-01-11
C018.zh
2018-05-30
C019.de
DKE, Andreas Boeumler
C019.fr
IEC 121A/WG 17
C019.zh
SAC, Li Hui
MDC_P001_5
0112/2///62683#ACG250
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2020-01-11
MDC_P003_1
2016-02-01
MDC_P003_2
2020-01-11
MDC_P003_3
2020-01-11
MDC_P004.de
Anschlussmöglichkeiten
MDC_P004.en
Connection facilities
MDC_P004.fr
Eléments de raccordement
MDC_P004.zh
连接件
MDC_P006.de
Anschlüsse, Schrauben oder andere Teile, die für die elektrische Verbindung der Leitungen von externen Stromkreisen des Fußschalters verwendet werden
MDC_P006.en
terminals, screws or other parts, used for the electrical connection of conductors of external circuits of the foot switch
MDC_P006.fr
bornes, vis et autres pièces, utilisées pour le raccordement électrique aux conducteurs des circuits externes de l'interrupteur à pédale
MDC_P006.zh
端子、螺钉或其他部件,用于与脚踏开关外部电路的电气连接
MDC_P010
0112/2///62683#ACG000
MDC_P011
ITEM_CLASS
MDC_P012
IEC SC121A
MDC_P013
{0112/2///62683#ACC068}
MDC_P090
{0112/2///62683#ACE850,0112/2///62683#ACE875,0112/2///62683#ACE876}

Version history1#

  1. Current rev 01
    11 Jan 2020 · 22:19 UTC by BATCH 00000747
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.