v1rev 12025-09-26IEC 62061:2021, 3.2.4

safety subsystem

0112/2///62683#ACH687

entity of the top-level architectural design of a safety-related system where a dangerous failure of the subsystem results in dangerous failure of a safety function

value term
Enumeration code
ACH687

Metadata#

Synonyms
  • subsystem(device type 1)
Note
Note 1 to entry: This differs from common language where “subsystem” may mean any sub-divided part of an entity, the term “subsystem” is used in this document within a strongly defined hierarchy of terminology: “subsystem” is the first level subdivision of a system. The parts resulting from further subdivision of a subsystem are called “subsystem elements”. Note 2 to entry: A complete subsystem can be made up from a number of identifiable and separate subsystem elements. Note 3 to entry: The subsystem specification includes its role in the safety function and its interface with the other subsystems of the SCS. Note 4 to entry: One subsystem can be part of several safety functions, e.g. the same combination of contactors can be used to de-energise a motor either in the event of detection of a person in a danger zone or also in the event of opening an interlock guard.
Source document
IEC 62061:2021, 3.2.4
Version
1
Revision
1
Status
Standard
Publisher
IEC
Responsible committee
IEC/TC 121
Change request
C00094
Dates
  • Original: 2025-09-26
  • Current version: 2025-09-26
  • Current revision: 2025-09-26