installation conditions
conditions under which a given object shall be physically installed for its operation according to the manufacturer's specification
Hierarchy#
Ancestors (top) → ADA073 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes2#
Declared properties13#
code of the mounting features which are designed to fasten a component to its counterpart
mounted height of a component referred to its seating plane
area occupied in the seating plane of the geometrical object defined by its effective physical contour
area occupied in the seating plane of the geometrical object defined due to installation, protection, operation, service and maintenance reasons
volume of a three-dimensional space defining the effective physical contours of a geometrical object
three-dimensional space associated with a geometrical object due to installation, protection, operation, service and maintenance reasons
distance on the x-axis of the direction of the preferred mounting position of a component
distance on the y-axis of the direction of the preferred mounting position of a component
distance on the z-axis of the direction of the preferred mounting position of a component
angle indicating the maximum rotation deviation from the y-axis within the y/z plane of the three-dimensional coordinate system, under which the device fulfils its terms of operation
angle indicating the maximum rotation deviation from the y-axis within the y/x plane of the three-dimensional coordinate system, under which the device fulfils its terms of operation
human readible information on putting something (such as a piece of equipment) together and making it ready for use
reason providing information why a space is considered to be a forbidden space
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 2
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Responsible committee
- IEC/SC 3D
- Change request
C00115- Dates
- Current version: 2023-04-17
- Current revision: 2023-04-17
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (15 keys from source .xls) — click to expand
- C002
- C00115
- C011
- IEC
- C016
- Standard
- MDC_P001_5
- 0112/2///61360_4#ADA073
- MDC_P002_1
- 2
- MDC_P002_2
- 1
- MDC_P003_0
- 2023-04-17
- MDC_P003_2
- 2023-04-17
- MDC_P003_3
- 2023-04-17
- MDC_P004.en
- installation conditions
- MDC_P006.en
- conditions under which a given object shall be physically installed for its operation according to the manufacturer's specification
- MDC_P010
- 0112/2///61360_4#AAA233
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 3D
- MDC_P014
- {0112/2///61360_4#AAE006,0112/2///61360_4#AAE027,0112/2///61360_4#AAF397,0112/2///61360_4#AAF398,0112/2///61360_4#AAF399,0112/2///61360_4#AAF400,0112/2///61360_4#AAF401,0112/2///61360_4#AAF402,0112/2///61360_4#AAF403,0112/2///61360_4#AAF404,0112/2///61360_4#AAF405,0112/2///61360_4#AAF433,0112/2///61360_4#ADA074}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.