measures for maintainability and maintenance support related concepts
concept of measures for describing the maintainability and maintenance support of an item
Hierarchy#
Ancestors (top) → ADA229 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties27#
part of the maintenance time taken to perform corrective maintenance, including technical delays and logistic delays inherent in corrective maintenance
part of the active maintenance time taken to perform a preventive maintenance
part of the active preventive maintenance time taken to perform a preventive maintenance action
part of the active maintenance time taken to perform a corrective maintenance action
time interval between failure and detection of the resulting fault
delay to maintenance action incurred for administrative reasons
delay, excluding administrative delay, incurred for the provision of resources needed for a maintenance action to proceed or continue
part of active corrective maintenance time taken to perform fault correction
delay incurred in performing auxiliary technical actions associated with, but not part of, the maintenance action
part of active maintenance time taken to complete function checkout
part of active corrective maintenance time taken to complete fault diagnosis
part of active corrective maintenance time taken to complete fault localization
part of active corrective maintenance time taken to complete repair action
limit, if it exists, of the quotient of the conditional probability that the repair is completed within time interval (t, t + Δt) and Δt, when Δt tends to zero, given that the repair started at t = 0 and had not been completed before time t
expectation of the repair time
expectation of the active corrective maintenance time
expectation of the time to restoration
proportion of faults that can be detected, under given conditions
proportion of detected faults that can be successfully corrected
expectation of the administrative delay
expectation of the logistic delay
probability that a given maintenance action, performed under stated conditions and using specified procedures and resources, can be completed within the time interval (t1, t2) given that the action started at t = 0
duration of maintenance, including active maintenance time, and technical and logistic delays incurred, for a given maintenance action
sum of the durations of time spent by individual persons to carry out a specified maintenance action
duration of a maintenance action, excluding logistic delay
part of the maintenance time taken to perform preventive maintenance, including technical delays and logistic delays inherent in preventive maintenance
time interval, from the instant of failure, until restoration
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Source document
- IEV 192-07:2015
- Version
- 3
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Responsible committee
- IEC/SC 3D
- Change request
C00115- Dates
- Current version: 2023-04-17
- Current revision: 2023-04-17
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (17 keys from source .xls) — click to expand
- C002
- C00115
- C011
- IEC
- C016
- Standard
- MDC_P001_5
- 0112/2///61360_4#ADA229
- MDC_P002_1
- 3
- MDC_P002_2
- 1
- MDC_P003_0
- 2023-04-17
- MDC_P003_2
- 2023-04-17
- MDC_P003_3
- 2023-04-17
- MDC_P004.de
- Messgrößen für Instandhaltbarkeits- und Instandhaltungsbereitschaftskonzepte
- MDC_P004.en
- measures for maintainability and maintenance support related concepts
- MDC_P006_1
- IEV 192-07:2015
- MDC_P006.en
- concept of measures for describing the maintainability and maintenance support of an item
- MDC_P010
- 0112/2///61360_4#ADA137
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 3D
- MDC_P014
- {0112/2///61360_4#ADA286,0112/2///61360_4#ADA287,0112/2///61360_4#ADA288,0112/2///61360_4#ADA289,0112/2///61360_4#ADA290,0112/2///61360_4#ADA291,0112/2///61360_4#ADA170,0112/2///61360_4#ADA171,0112/2///61360_4#ADA172,0112/2///61360_4#ADA173,0112/2///61360_4#ADA174,0112/2///61360_4#ADA175,0112/2///61360_4#ADA176,0112/2///61360_4#ADA177,0112/2///61360_4#ADA178,0112/2///61360_4#ADA179,0112/2///61360_4#ADA180,0112/2///61360_4#ADA181,0112/2///61360_4#ADA182,0112/2///61360_4#ADA183,0112/2///61360_4#ADA184,0112/2///61360_4#ADA185,0112/2///61360_4#ADA186,0112/2///61360_4#ADA187,0112/2///61360_4#ADA188,0112/2///61360_4#ADA189,0112/2///61360_4#ADA190}
Version history3#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.