v1rev 12019-05-27IEV 192-05-08:2015-02
instantaneous failure intensity
0112/2///61360_4#ADA198
limit, if it exists, of the quotient of the mean number of failures of a repairable item within time interval (t, t + Δt), by Δt, when Δt tends to zero z(t)=limΔt→0+E[N(t+Δt)−N(t)]Δt z(t)=limΔt→0+E[N(t+Δt)−N(t)]Δt where N(t) is the number of failures in the time interval (0, t), where E denotes the expectation.
- Used by classes
- 1
- Code
ADA198- Data type
- REAL_MEASURE_TYPEmeasure
- Unit
- UAA000 UAA000
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.
Metadata#
- Note
- Other terms used for failure intensity are “rate of occurrence of failures”, and “failure frequency”.
- Source document
- IEV 192-05-08:2015-02
- Version
- 1
- Revision
- 1
- Status
- Standard
- Dates
- Current version: 2019-05-27
- Current revision: 2019-05-27