t_rrv1rev 42013-04-24IEC 61360-4 AAE281
reverse recovery time
0112/2///61360_4#AFD073
time required for the reverse current of a diode to recover to a specified value, when switched from a specified forward current to a specified reverse voltage, at specified conditions
- Used by classes
- 1
- Code
AFD073- Data type
- LEVEL(TYP,MAX) OF REAL_MEASURE_TYPE
- Unit
- UAA972 UAA972
Version history4#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.
Metadata#
- Note
- The reverse recovery time is measured as the time interval between t0, the point where the forward current crosses the zero current axis, and the instant when for decreasing values of iR a line through the points for 0.9 IRM and 0.25 IRM crosses the zero current axis.
- Source document
- IEC 61360-4 AAE281
- Version
- 1
- Revision
- 4
- Status
- Standard
- Dates
- Current version: 2013-04-24
- Current revision: 2015-08-17