Skip to content
OpenCDD
classITEM_CLASSv2rev 22018-03-20

Guided-wave level switch

0112/2///61987#ABA722

wave level switch that emits a wave that is guided by a rod, cable or rope to the surface of process material and uses the time of flight of the reflected wave to detect a level regime

Inherited
2

Hierarchy#

Ancestors (top) → ABA722 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes6#

Declared properties1#

Inherited properties (2) — click to expand

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
2
Revision
2
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
IEC/SC 65E
Change request
C00146
Dates
  • Original: 2013-08-27
  • Current version: 2018-03-20
  • Current revision: 2023-11-22

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (28 keys from source .xls) — click to expand
C002
C00146
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C017.fr
0
C018.de
2014-12-27
C018.fr
2014-12-27
C019.de
Mr. W. Hartmann
C019.fr
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABA722
MDC_P002_1
2
MDC_P002_2
2
MDC_P003_0
2023-11-22
MDC_P003_1
2013-08-27
MDC_P003_2
2018-03-20
MDC_P003_3
2023-11-22
MDC_P004.de
Geführte Mikrowellen-Grenzstandschalter
MDC_P004.en
Guided-wave level switch
MDC_P004.fr
Commutateur de niveau à ondes guidées
MDC_P006.de
Grenzstandschalter basierend auf Wellen, der eine Welle aussendet, die durch einen Stab, ein Kabel oder Seil zur Oberfläche des Prozessstoffs geführt wird und die Laufzeit der reflektierten Welle nutzt, um einen Füllstandzustand zu ermitteln
MDC_P006.en
wave level switch that emits a wave that is guided by a rod, cable or rope to the surface of process material and uses the time of flight of the reflected wave to detect a level regime
MDC_P006.fr
commutateur de niveau à ondes émettant une onde qui est guidée par une tige, un câble ou une corde à la surface du matériau du processus et utilise le temps de vol de l'onde réfléchie pour détecter un niveau
MDC_P010
0112/2///61987#ABA720
MDC_P011
ITEM_CLASS
MDC_P012
IEC/SC 65E
MDC_P014
{0112/2///61987#ABF874}
MDC_P019
true

Version history4#

  1. Current rev 02
    22 Nov 2023 · 15:56 UTC by BATCH 00000816
    View on cdd.iec.ch ↗
  2. superseded rev 01
    28 Mar 2018 · 07:25 UTC by BATCH 00000762
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 02
    01 Mar 2017 · 14:49 UTC by BATCH 00000732
    ↓ Version JSON
    View on cdd.iec.ch ↗
  4. superseded rev 01
    07 Apr 2014 · 09:39 UTC by BATCH 00000696
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.