Skip to content
OpenCDD
classITEM_CLASSv3rev 12020-02-24

Totalizer indicator [2]

0112/2///61987#ABC040

properties characterizing a mechanical totalizer supplied with the device

Hierarchy#

Ancestors (top) → ABC040 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties31#

31 / 31
ABA183style of totalizerENUM_STRING_TYPE

classification of a transmitter, totalizer or indicator according to its arrangement with respect to the device body

ABA184type of fasteningENUM_STRING_TYPE

classification of a fixation of a device or component according to the method of mounting

ABA185counter resetENUM_STRING_TYPE

ability of a counter to be reset

ABA187type of totalizerENUM_STRING_TYPE

classification of totalizer action according to direction and counting function

ABA190totalizer unitSTRING_TYPE

short name of the standardized unit of measure of a totalizer

ABA191style of indicatorENUM_STRING_TYPE

classification of an indicator according to the number of digits displayed

ABA193type of signal power sourceENUM_STRING_TYPE

designation of a device or component power according to source, nominal voltage, current mode and frequency

ABA558degree of protectionENUM_STRING_TYPE

extent of protection provided by an enclosure against access to hazardous parts, against ingress of solid foreign objects and/or ingress of water and verified by standardized test methods

ABA577PCE category and control functionTRANSLATABLE_STRING_TYPE

alphanumeric character sequence identifying the category and function of a process control engineering request

ABA588rated voltageREAL_MEASURE_TYPE

operating voltage of the device as defined by the manufacturer and to which certain device properties are referenced

ABA589type/level of protectionENUM_STRING_TYPE

set of specific measures applied to equipment to avoid ignition of a surrounding explosive atmosphere

ABA913heating mediumTRANSLATABLE_STRING_TYPE

heat carrier used to compensate for heat losses

ABA969type of voltageENUM_STRING_TYPE

classification of a power supply according to the time behaviour of the voltage

ABB074temperature spacerENUM_STRING_TYPE

provision of a mechanical extension intended to increase the distance of the electronics from the process, serving to increase the allowable process temperature

ABB076type of counterENUM_STRING_TYPE

classification of a mechanical counter according to its counting mechanism

ABB271tag nameNON_TRANSLATABLE_STRING_TYPE

alphanumeric character sequence uniquely identifying a measuring or control point

ABB393mounting locationENUM_STRING_TYPE

design of a device or a device component mounting classified by the type of surface on/to which it will be mounted

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
3
Revision
1
Status
Standard
Responsible committee
SC65E – IEC 61987
Change request
C00091
Dates
  • Original: 2017-12-07
  • Current version: 2020-02-24
  • Current revision: 2020-02-24

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (25 keys from source .xls) — click to expand
C002
C00091
C016
Standard
C017.de
0
C017.fr
0
C018.de
2014-12-12
C018.fr
2013-08-27
C019.de
Mr. W. Hartmann
C019.fr
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABC040
MDC_P002_1
3
MDC_P002_2
1
MDC_P003_0
2020-02-24
MDC_P003_1
2017-12-07
MDC_P003_2
2020-02-24
MDC_P003_3
2020-02-24
MDC_P004.de
Summenzähler [2]
MDC_P004.en
Totalizer indicator [2]
MDC_P004.fr
Indicateur de totalisateur [2]
MDC_P006.de
Merkmale, die einen mit dem Gerät gelieferten mechanischen Summenzähler kennzeichnen
MDC_P006.en
properties characterizing a mechanical totalizer supplied with the device
MDC_P006.fr
propriétés caractérisant un totalisateur mécanique fourni avec l’appareil (version de bloc 2)
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABB271,0112/2///61987#ABA577,0112/2///61987#ABA183,0112/2///61987#ABB393,0112/2///61987#ABA184,0112/2///61987#ABB502,0112/2///61987#ABB074,0112/2///61987#ABB076,0112/2///61987#ABA185,0112/2///61987#ABA892,0112/2///61987#ABA187,0112/2///61987#ABA189,0112/2///61987#ABA190,0112/2///61987#ABA952,0112/2///61987#ABA191,0112/2///61987#ABB124,0112/2///61987#ABA192,0112/2///61987#ABA589,0112/2///61987#ABA558,0112/2///61987#ABA179,0112/2///61987#ABB386,0112/2///61987#ABC976,0112/2///61987#ABA913,0112/2///61987#ABA588,0112/2///61987#ABA969,0112/2///61987#ABA193,0112/2///61987#ABC859,0112/2///61987#ABB177,0112/2///61987#ABC803,0112/2///61987#ABC012,0112/2///61987#ABC861}

Version history4#

  1. Current rev 01
    24 Feb 2020 · 11:58 UTC by BATCH 00000774
    View on cdd.iec.ch ↗
  2. superseded rev 01
    28 Mar 2018 · 07:25 UTC by BATCH 00000762
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 02
    18 Jun 2014 · 13:34 UTC by BATCH 00000701
    ↓ Version JSON
    View on cdd.iec.ch ↗
  4. superseded rev 01
    08 Apr 2014 · 17:24 UTC by BATCH 00000699
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.