Totalizer indicator [2]
properties characterizing a mechanical totalizer supplied with the device
Hierarchy#
Ancestors (top) → ABC040 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties31#
degree of ingress protection offered by a housing or enclosure
classification of a transmitter, totalizer or indicator according to its arrangement with respect to the device body
classification of a fixation of a device or component according to the method of mounting
ability of a counter to be reset
classification of totalizer action according to direction and counting function
classification of a totalizer reset facility according to its location
short name of the standardized unit of measure of a totalizer
classification of an indicator according to the number of digits displayed
number of poles and throws provided by a switch
designation of a device or component power according to source, nominal voltage, current mode and frequency
extent of protection provided by an enclosure against access to hazardous parts, against ingress of solid foreign objects and/or ingress of water and verified by standardized test methods
alphanumeric character sequence identifying the category and function of a process control engineering request
operating voltage of the device as defined by the manufacturer and to which certain device properties are referenced
set of specific measures applied to equipment to avoid ignition of a surrounding explosive atmosphere
ability of a counter to be preset
heat carrier used to compensate for heat losses
alphanumeric character sequence identifying a head transmitter
classification of a power supply according to the time behaviour of the voltage
provision of a mechanical extension intended to increase the distance of the electronics from the process, serving to increase the allowable process temperature
classification of a mechanical counter according to its counting mechanism
classification of a pulse generator according to its mechanical form
@number of connection facilities
alphanumeric character sequence uniquely identifying a measuring or control point
standard to which a statement on an enclosure protection type or class refers
design of a device or a device component mounting classified by the type of surface on/to which it will be mounted
angle of a fastening measure with respect to the vertical
@number of equipotential bonding connections
reference to block ABC173
reference to block ABC229
reference to block ABC231
reference to block ABC346
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 3
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00091- Dates
- Original: 2017-12-07
- Current version: 2020-02-24
- Current revision: 2020-02-24
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00091
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC040
- MDC_P002_1
- 3
- MDC_P002_2
- 1
- MDC_P003_0
- 2020-02-24
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2020-02-24
- MDC_P003_3
- 2020-02-24
- MDC_P004.de
- Summenzähler [2]
- MDC_P004.en
- Totalizer indicator [2]
- MDC_P004.fr
- Indicateur de totalisateur [2]
- MDC_P006.de
- Merkmale, die einen mit dem Gerät gelieferten mechanischen Summenzähler kennzeichnen
- MDC_P006.en
- properties characterizing a mechanical totalizer supplied with the device
- MDC_P006.fr
- propriétés caractérisant un totalisateur mécanique fourni avec l’appareil (version de bloc 2)
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB271,0112/2///61987#ABA577,0112/2///61987#ABA183,0112/2///61987#ABB393,0112/2///61987#ABA184,0112/2///61987#ABB502,0112/2///61987#ABB074,0112/2///61987#ABB076,0112/2///61987#ABA185,0112/2///61987#ABA892,0112/2///61987#ABA187,0112/2///61987#ABA189,0112/2///61987#ABA190,0112/2///61987#ABA952,0112/2///61987#ABA191,0112/2///61987#ABB124,0112/2///61987#ABA192,0112/2///61987#ABA589,0112/2///61987#ABA558,0112/2///61987#ABA179,0112/2///61987#ABB386,0112/2///61987#ABC976,0112/2///61987#ABA913,0112/2///61987#ABA588,0112/2///61987#ABA969,0112/2///61987#ABA193,0112/2///61987#ABC859,0112/2///61987#ABB177,0112/2///61987#ABC803,0112/2///61987#ABC012,0112/2///61987#ABC861}
Version history4#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.