Multichannel radiation thermometer with multiple independent detectors
multichannel radiation thermometer with more than two detectors, in which the radiation is divided with a beam splitter and more than two filters into more than two distinct spectral ranges
- Inherited
- 3
Hierarchy#
Ancestors (top) → ABE353 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes10#
ABA000Equipment for industrial-process automationABV000CharacterizationABA001Measuring instrumentABA751TransmitterABA835Temperature transmitterABE363Non-contact temperature transmitterABA836Radiation temperature transmitterABE340Point temperature measuring deviceABE341Radiation thermometerABE351Multichannel radiation thermometer
Declared properties#
No declared properties
This class does not declare any properties of its own.
Inherited properties (3) — click to expand
reference to block ABE761
ABF896reference to Operating LOP for temperature measuring equipmentCLASS_REFERENCE_TYPE(0112/2///61987#ABF867)reference to block ABF867
reference to block ABH525
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Note
- Dividing the radiation with beam splitter and more than two filters into more than two distinct spectral ranges, followed by analysis using more than two radiation detectors and the associated electronics.
- Version
- 1
- Revision
- 2
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00146- Dates
- Current version: 2016-05-24
- Current revision: 2023-11-22
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00146
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-12
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABE353
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2023-11-22
- MDC_P003_2
- 2016-05-24
- MDC_P003_3
- 2023-11-22
- MDC_P004.de
- Mehrkanal-Strahlungsthermometer mit unabhängigen Mehrfachdetektoren
- MDC_P004.en
- Multichannel radiation thermometer with multiple independent detectors
- MDC_P006.de
- Mehrkanal-Strahlungsthermometer mit mehr als zwei Detektoren, in dem die Strahlung mit einem Strahlteiler und mit mehr als zwei Filtern in zwei getrennte Wellenlängenbereiche aufgeteilt wird
- MDC_P006.en
- multichannel radiation thermometer with more than two detectors, in which the radiation is divided with a beam splitter and more than two filters into more than two distinct spectral ranges
- MDC_P008.de
- Indem die Strahlung mit Strahlteilern und mehr als zwei Filtern in mehr als zwei unterschiedliche Spektralbereichen aufgeteilt wird, gefolgt von einer Analyse, die mehr als zwei Strahlungsdetektoren und zugehörige Elektronik verwendet.
- MDC_P008.en
- Dividing the radiation with beam splitter and more than two filters into more than two distinct spectral ranges, followed by analysis using more than two radiation detectors and the associated electronics.
- MDC_P010
- 0112/2///61987#ABE351
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P019
- true
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.