Line scanner

0112/2///61987#ABE356

line temperature measuring device with a single detector that samples radiation sequentially along a line by opto-mechanical means

Inherited
2

Hierarchy#

Ancestors (top) → ABE356 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes8#

Declared properties#

No declared properties

This class does not declare any properties of its own.

Inherited properties (2) — click to expand

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Note
Line scanners use a high-speed rotating scanning mirror integrated into the instrument in combination with imaging optics and a single detector with a very small time constant. Points on the measured object are sampled sequentially along a line.
Version
1
Revision
2
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
IEC/SC 65E
Change request
C00146
Dates
  • Current version: 2016-05-24
  • Current revision: 2023-11-22

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (23 keys from source .xls) — click to expand
C002
C00146
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C018.de
2014-12-12
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABE356
MDC_P002_1
1
MDC_P002_2
2
MDC_P003_0
2023-11-22
MDC_P003_2
2016-05-24
MDC_P003_3
2023-11-22
MDC_P004.de
Linienscanner
MDC_P004.en
Line scanner
MDC_P006.de
Linien-Temperaturmessgerät mit einem Einzeldetektor, das Strahlung entlang einer Linie sequenziell mit opto-mechanischen Mitteln erfasst
MDC_P006.en
line temperature measuring device with a single detector that samples radiation sequentially along a line by opto-mechanical means
MDC_P008.de
Linienscanner benutzen einen rotierenden Hochgeschwindigkeitsspiegel, der in das Gerät zusammen mit Bildoptik und einem Einzeldetektor mit sehr geringer Zeitkonstante integriert ist. Punkte auf dem Messobjekt werden sequenziell entlang einer Linie erfasst.
MDC_P008.en
Line scanners use a high-speed rotating scanning mirror integrated into the instrument in combination with imaging optics and a single detector with a very small time constant. Points on the measured object are sampled sequentially along a line.
MDC_P010
0112/2///61987#ABE355
MDC_P011
ITEM_CLASS
MDC_P012
IEC/SC 65E
MDC_P019
true

Version history2#

  1. Current rev 02
    22 Nov 2023 · 15:56 UTC by BATCH 00000816
    View on cdd.iec.ch ↗
  2. superseded rev 01
    28 Mar 2018 · 07:26 UTC by BATCH 00000762
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.