Performance of non-contact temp. transmitter/radiation temp. transmitter
properties characterizing the accuracy of a non-contact temperature transmitter or radiation temperature transmitter
Hierarchy#
Ancestors (top) → ABF003 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties8#
contribution of the measurement uncertainty which is due to instrument noise
relative difference in the radiance or temperature reading of the radiation thermometer when the size of the radiating area of the observed source is changed
twice the standard deviation of measurements repeated under the same conditions within a very short time span (of several minutes)
maximum deviation between the readings of two instruments of the same type operating under identical conditions divided by two
smallest detectable increment between two temperature values
time interval an abrupt change in the value of the input parameter (object temperature or object radiation) has to be present, such that the output value of the radiation thermometer reaches a given measurement value
time interval between the instant of an abrupt change in the value of the input parameter (object temperature or object radiation) and the instant from which the measured value of the radiation thermometer (output parameter) remains within specified limits of its final value
additional uncertainty of the measured temperature value depending on the relative air humidity at a defined ambient temperature
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 2
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00200- Dates
- Original: 2017-12-07
- Current version: 2017-12-07
- Current revision: 2026-05-04
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00200
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABF003
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2026-05-04
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2017-12-07
- MDC_P003_3
- 2026-05-04
- MDC_P004.de
- Leistungsdaten berührungsloser Temperaturmessumf./Strahlungs-Temperaturmessumf.
- MDC_P004.en
- Performance of non-contact temp. transmitter/radiation temp. transmitter
- MDC_P006.de
- Merkmale, die die Genauigkeit eines berührungslosen Temperaturmessumformers oder Strahlungs-Temperaturmessumformers kennzeichnen
- MDC_P006.en
- properties characterizing the accuracy of a non-contact temperature transmitter or radiation temperature transmitter
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABF227,0112/2///61987#ABF229,0112/2///61987#ABF230,0112/2///61987#ABF231,0112/2///61987#ABF232,0112/2///61987#ABF233,0112/2///61987#ABF234,0112/2///61987#ABF235}
- MDC_P019
- false