Structural design of a float level transmitter and switch
properties characterizing the constructional details of a float level transmitter and float level switch
Hierarchy#
Ancestors (top) → ABF025 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties18#
precautions taken or to be taken during manufacture of the device regarding wetted parts to ensure its safe operation under special operation conditions
classification of a component surface finish according to the method used to achieve it
tightness of a pressure or vacuum housing expressed in terms of the leakage rate to or from its environment
classification of a seal according to its construction
@number of additional wetted parts materials
@number of material of wetted inner seals
reference to block ABC339
reference to block ABC403
@number of floats
classification of a float switch according to its fastening or the mounting position of the float
classification of a float position detector according to according its electromechanical construction
reference to block ABF029
reference to block ABF040
reference to block ABF046
reference to block ABF050
classification of the means used to isolate against heat according to mechanical construction
reference to block ABH418
reference to block ABU458
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 2
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00200- Dates
- Original: 2017-12-07
- Current version: 2017-12-07
- Current revision: 2026-05-04
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00200
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-17
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABF025
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2026-05-04
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2017-12-07
- MDC_P003_3
- 2026-05-04
- MDC_P004.de
- Konstruktiver Aufbau Schwimmer-Füllstandmessumformer und -Grenzstandschalter
- MDC_P004.en
- Structural design of a float level transmitter and switch
- MDC_P006.de
- Merkmale, die die konstruktiven Details eines Schwimmer-Füllstandmessumformers und Schwimmer-Grenzstandschalters kennzeichnen
- MDC_P006.en
- properties characterizing the constructional details of a float level transmitter and float level switch
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABU164,0112/2///61987#ABF032,0112/2///61987#ABF033,0112/2///61987#ABF028,0112/2///61987#ABF701,0112/2///61987#ABF704,0112/2///61987#ABF707,0112/2///61987#ABF708,0112/2///61987#ABH411,0112/2///61987#ABH427,0112/2///61987#ABA147,0112/2///61987#ABA633,0112/2///61987#ABB140,0112/2///61987#ABB396,0112/2///61987#ABB915,0112/2///61987#ABD033,0112/2///61987#ABB457,0112/2///61987#ABC969}
- MDC_P019
- false
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.