Skip to content
OpenCDD
classITEM_CLASSv1rev 22017-12-07

Structural design of a float level transmitter and switch

0112/2///61987#ABF025

properties characterizing the constructional details of a float level transmitter and float level switch

Hierarchy#

Ancestors (top) → ABF025 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties18#

18 / 18

precautions taken or to be taken during manufacture of the device regarding wetted parts to ensure its safe operation under special operation conditions

ABA633type of surface finishENUM_STRING_TYPE

classification of a component surface finish according to the method used to achieve it

ABB140leak tightness to exteriorREAL_MEASURE_TYPE

tightness of a pressure or vacuum housing expressed in terms of the leakage rate to or from its environment

ABB396type of sealTRANSLATABLE_STRING_TYPE

classification of a seal according to its construction

ABF032type of float switchENUM_STRING_TYPE

classification of a float switch according to its fastening or the mounting position of the float

ABF701reference to FloatCLASS_REFERENCE_TYPE(0112/2///61987#ABF029)

reference to block ABF029

ABH411style of heat insulationENUM_STRING_TYPE

classification of the means used to isolate against heat according to mechanical construction

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
1
Revision
2
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
IEC/SC 65E
Change request
C00200
Dates
  • Original: 2017-12-07
  • Current version: 2017-12-07
  • Current revision: 2026-05-04

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (23 keys from source .xls) — click to expand
C002
C00200
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C018.de
2014-12-17
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABF025
MDC_P002_1
1
MDC_P002_2
2
MDC_P003_0
2026-05-04
MDC_P003_1
2017-12-07
MDC_P003_2
2017-12-07
MDC_P003_3
2026-05-04
MDC_P004.de
Konstruktiver Aufbau Schwimmer-Füllstandmessumformer und -Grenzstandschalter
MDC_P004.en
Structural design of a float level transmitter and switch
MDC_P006.de
Merkmale, die die konstruktiven Details eines Schwimmer-Füllstandmessumformers und Schwimmer-Grenzstandschalters kennzeichnen
MDC_P006.en
properties characterizing the constructional details of a float level transmitter and float level switch
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
IEC/SC 65E
MDC_P014
{0112/2///61987#ABU164,0112/2///61987#ABF032,0112/2///61987#ABF033,0112/2///61987#ABF028,0112/2///61987#ABF701,0112/2///61987#ABF704,0112/2///61987#ABF707,0112/2///61987#ABF708,0112/2///61987#ABH411,0112/2///61987#ABH427,0112/2///61987#ABA147,0112/2///61987#ABA633,0112/2///61987#ABB140,0112/2///61987#ABB396,0112/2///61987#ABB915,0112/2///61987#ABD033,0112/2///61987#ABB457,0112/2///61987#ABC969}
MDC_P019
false

Version history2#

  1. Current rev 02
    04 May 2026 · 14:34 UTC by BATCH 00000863
    View on cdd.iec.ch ↗
  2. superseded rev 01
    28 Mar 2018 · 07:26 UTC by BATCH 00000762
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.