Skip to content
OpenCDD
classITEM_CLASSv2rev 12022-12-09

Accuracy expressed as a percentage [6]

0112/2///61987#ABJ595

properties characterizing the accuracy of a measured value or a signal expressed as a percentage of reading, span or full range etc.

Hierarchy#

Ancestors (top) → ABJ595 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties27#

27 / 27
ABA568non-repeatabilityREAL_MEASURE_TYPE

algebraic difference between the extreme values obtained by a number of consecutive measurements of the output over a short period of time for the same value of the input under the same operating conditions, approaching from the same direction, for full range traverses

largest positive or negative value of error of the average upscale or downscale value at each point of measurement expressed as a percentage of range, span or measured value

ABB653inaccuracy expressed as percentageREAL_MEASURE_TYPE

maximum positive and negative deviation from the specified characteristic curve observed in testing a device under specified conditions and by a specified procedure, expressed as percentage of ideal span

ABB655span errorREAL_MEASURE_TYPE

difference between the actual span and the ideal span, expressed as percentage of ideal span

ABB656zero point errorREAL_MEASURE_TYPE

absolute error of a device under reference conditions, when the input is at the lower range value

ABB661hysteresisREAL_MEASURE_TYPE

difference between consecutive upscale and downscale outputs for any single test cycle at the same input test point

ABB662percentage deadbandREAL_MEASURE_TYPE

finite range of values within which variation of the input variable does not produce any noticeable change in the output variable

ABB801non-linearity (terminal-based)REAL_MEASURE_TYPE

non-linearity determined by drawing a straight line so that it coincides, with the average calibration curve at the upper range value and at the lower range value

ABB802non-linearity (zero-based)REAL_MEASURE_TYPE

non-linearity determined by drawing a straight line so that it coincides with, the average calibration curve at the lower range value (zero), and minimizes the maximum, deviation

ABB803non-linearity (independent)REAL_MEASURE_TYPE

non-linearity determined by drawing a straight line through the average, curve in such a way as to minimize the maximum deviation

ABB804non-conformity (terminal-based)REAL_MEASURE_TYPE

non-conformity determined by drawing a straight line so that it coincides, with the average calibration curve at the upper range value and at the lower range value

ABB805non-conformity (zero-based)REAL_MEASURE_TYPE

non-conformity determined by drawing a straight line so that it coincides with, the average calibration curve at the lower range value (zero), and minimizes the maximum, deviation

ABB806non-conformity (independent)REAL_MEASURE_TYPE

non-conformity determined by drawing a straight line through the average, curve in such a way as to minimize the maximum deviation

classification of a non-linearity/non-conformity statement based on the method used to determine inaccuracy according to IEC 61298-2:2008, 4.1.8

ABB847formula for inaccuracyNON_TRANSLATABLE_STRING_TYPE

equation from which the inaccuracy of a device can be calculated

ABD459accuracy expressed as percentageREAL_MEASURE_TYPE

quality which characterizes the ability of a measuring instrument to provide an indicated value close to a true value of the measurand expressed as a percentage of reading, span or full range etc. under reference conditions

ABD535confidence levelENUM_STRING_TYPE

probability, generally expressed as a percentage, that the true value of a statistically estimated quantity falls within a pre-established interval about the estimated value

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
2
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
IEC/SC 65E
Change request
C00112
Dates
  • Original: 2017-12-07
  • Current version: 2022-12-09
  • Current revision: 2022-12-09

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (28 keys from source .xls) — click to expand
C002
C00112
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
1
C017.fr
0
C018.de
2021-08-12
C018.fr
2017-02-04
C019.de
Mr. W. Hartmann
C019.fr
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABJ595
MDC_P002_1
2
MDC_P002_2
1
MDC_P003_0
2022-12-09
MDC_P003_1
2017-12-07
MDC_P003_2
2022-12-09
MDC_P003_3
2022-12-09
MDC_P004.de
Genauigkeit in relativen Einheiten [6]
MDC_P004.en
Accuracy expressed as a percentage [6]
MDC_P004.fr
Exactitude exprimée en pourcentage
MDC_P006.de
Merkmale, die die Genauigkeit eines Messwertes oder eines Signals, ausgedrückt als relativer Wert bezogen auf den Wert selbst, die Spanne, die maximale Spanne usw. kennzeichnen
MDC_P006.en
properties characterizing the accuracy of a measured value or a signal expressed as a percentage of reading, span or full range etc.
MDC_P006.fr
propriétés caractérisant l’exactitude d’une mesure, exprimée en pourcentage de lecture, intervalle de mesure ou étendue totale, etc
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
IEC/SC 65E
MDC_P014
{0112/2///61987#ABD459,0112/2///61987#ABD460,0112/2///61987#ABD535,0112/2///61987#ABB652,0112/2///61987#ABB005,0112/2///61987#ABB653,0112/2///61987#ABB654,0112/2///61987#ABB655,0112/2///61987#ABB656,0112/2///61987#ABA568,0112/2///61987#ABB779,0112/2///61987#ABB657,0112/2///61987#ABC707,0112/2///61987#ABB801,0112/2///61987#ABB802,0112/2///61987#ABB803,0112/2///61987#ABB804,0112/2///61987#ABB805,0112/2///61987#ABB806,0112/2///61987#ABB846,0112/2///61987#ABB661,0112/2///61987#ABB662,0112/2///61987#ABB663,0112/2///61987#ABB519,0112/2///61987#ABB774,0112/2///61987#ABB847,0112/2///61987#ABJ594}
MDC_P019
false

Version history2#

  1. Current rev 01
    09 Dec 2022 · 09:47 UTC by BATCH 00000803
    View on cdd.iec.ch ↗
  2. superseded rev 01
    28 Mar 2018 · 07:26 UTC by BATCH 00000762
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.