Density profile computer
calculator that uses two or more input signals to output the density as a function of depth
- Inherited
- 2
Hierarchy#
Ancestors (top) → ABN986 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes4#
Declared properties#
No declared properties
This class does not declare any properties of its own.
Inherited properties (2) — click to expand
ABP285reference to Operating LOP for infrastructure devicesCLASS_REFERENCE_TYPE(0112/2///61987#ABP284)reference to block ABP284
reference to block ABH525
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Note
- Input signals are usually provided by nuclear level transmitters and the medium is usually a mixture of water and oil.
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987-31
- Responsible committee
- IEC/SC 65E
- Change request
C00127- Dates
- Original: 2022-10-26
- Current version: 2022-10-26
- Current revision: 2022-10-26
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (24 keys from source .xls) — click to expand
- C002
- C00127
- C011
- IEC
- C012
- IEC 61987-31
- C016
- Standard
- C017.de
- 0
- C018.de
- 2022-07-25
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABN986
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2022-10-26
- MDC_P003_1
- 2022-10-26
- MDC_P003_2
- 2022-10-26
- MDC_P003_3
- 2022-10-26
- MDC_P004.de
- Dichteprofil-Rechner
- MDC_P004.en
- Density profile computer
- MDC_P006.de
- Rechner, der zwei oder mehr Eingangssignale verwendet, um die Dichte als Funktion der Tiefe auszugeben
- MDC_P006.en
- calculator that uses two or more input signals to output the density as a function of depth
- MDC_P008.de
- Die Eingangssignale werden in der Regel von einem radiometrischen Füllstandmessgerät geliefert und das Medium ist in der Regel ein Gemisch aus Wasser und Öl.
- MDC_P008.en
- Input signals are usually provided by nuclear level transmitters and the medium is usually a mixture of water and oil.
- MDC_P010
- 0112/2///61987#ABN985
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P019
- true