Skip to content
OpenCDD
classITEM_CLASSv1rev 12023-01-23

Accuracy expressed as a percentage [I/O module]

0112/2///61987#ABP013

properties characterizing the accuracy of a measurement of an I/O module, expressed as a percentage of reading, span or full range etc.

Hierarchy#

Ancestors (top) → ABP013 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties16#

16 / 16
ABA568non-repeatabilityREAL_MEASURE_TYPE

algebraic difference between the extreme values obtained by a number of consecutive measurements of the output over a short period of time for the same value of the input under the same operating conditions, approaching from the same direction, for full range traverses

ABB661hysteresisREAL_MEASURE_TYPE

difference between consecutive upscale and downscale outputs for any single test cycle at the same input test point

ABB662percentage deadbandREAL_MEASURE_TYPE

finite range of values within which variation of the input variable does not produce any noticeable change in the output variable

ABB801non-linearity (terminal-based)REAL_MEASURE_TYPE

non-linearity determined by drawing a straight line so that it coincides, with the average calibration curve at the upper range value and at the lower range value

ABB802non-linearity (zero-based)REAL_MEASURE_TYPE

non-linearity determined by drawing a straight line so that it coincides with, the average calibration curve at the lower range value (zero), and minimizes the maximum, deviation

ABB803non-linearity (independent)REAL_MEASURE_TYPE

non-linearity determined by drawing a straight line through the average, curve in such a way as to minimize the maximum deviation

ABB804non-conformity (terminal-based)REAL_MEASURE_TYPE

non-conformity determined by drawing a straight line so that it coincides, with the average calibration curve at the upper range value and at the lower range value

ABB805non-conformity (zero-based)REAL_MEASURE_TYPE

non-conformity determined by drawing a straight line so that it coincides with, the average calibration curve at the lower range value (zero), and minimizes the maximum, deviation

ABB806non-conformity (independent)REAL_MEASURE_TYPE

non-conformity determined by drawing a straight line through the average, curve in such a way as to minimize the maximum deviation

classification of a non-linearity/non-conformity statement based on the method used to determine inaccuracy according to IEC 61298-2:2008, 4.1.8

ABD459accuracy expressed as percentageREAL_MEASURE_TYPE

quality which characterizes the ability of a measuring instrument to provide an indicated value close to a true value of the measurand expressed as a percentage of reading, span or full range etc. under reference conditions

ABD535confidence levelENUM_STRING_TYPE

probability, generally expressed as a percentage, that the true value of a statistically estimated quantity falls within a pre-established interval about the estimated value

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
1
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
IEC/SC 65E
Change request
C00128
Dates
  • Original: 2023-01-23
  • Current version: 2023-01-23
  • Current revision: 2023-01-23

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (23 keys from source .xls) — click to expand
C002
C00128
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C018.de
2021-11-23
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABP013
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2023-01-23
MDC_P003_1
2023-01-23
MDC_P003_2
2023-01-23
MDC_P003_3
2023-01-23
MDC_P004.de
Genauigkeit in relativen Einheiten [I/O-Modul]
MDC_P004.en
Accuracy expressed as a percentage [I/O module]
MDC_P006.de
Merkmale, die die Genauigkeit einer Messung eines I/O-Moduls, ausgedrückt als relativer Wert bezogen auf den Messwert, die Messspanne, die maximale Messspanne usw. kennzeichnen
MDC_P006.en
properties characterizing the accuracy of a measurement of an I/O module, expressed as a percentage of reading, span or full range etc.
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
IEC/SC 65E
MDC_P014
{0112/2///61987#ABD459,0112/2///61987#ABD460,0112/2///61987#ABD535,0112/2///61987#ABA568,0112/2///61987#ABB779,0112/2///61987#ABB801,0112/2///61987#ABB802,0112/2///61987#ABB803,0112/2///61987#ABB804,0112/2///61987#ABB805,0112/2///61987#ABB806,0112/2///61987#ABB846,0112/2///61987#ABB661,0112/2///61987#ABB662,0112/2///61987#ABB663,0112/2///61987#ABP238}
MDC_P019
false

Version history1#

  1. Current rev 01
    23 Jan 2023 · 14:53 UTC by BATCH 00000807
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.