Optical fluorescence quenching sensor-specific cond. monitoring variables
properties characterizing dynamic data which are diagnostic results generated for an optical fluorescence quenching sensor
Hierarchy#
Ancestors (top) → ABP491 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties8#
number of times a sensor has been cleaned in place
number of times a sensor has been sterilized in place
temperature measured at a sensing element
time that can elapse until the next calibration, calculated from the configured calibration interval or estimated by the device
t90 settling time determined by the last calibration
absolute air pressure under which the last calibration was performed
slope of an optical fluorescence quenching sensing element characteristic determined by the last calibration
ABP587zero point of an optical fluorescence quenching sensing element characteristicREAL_MEASURE_TYPEzero point of an optical fluorescence quenching sensing element characteristic determined by the last calibration
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 2
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00200- Dates
- Original: 2023-03-06
- Current version: 2025-02-24
- Current revision: 2026-05-04
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00200
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2023-03-06
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABP491
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2026-05-04
- MDC_P003_1
- 2023-03-06
- MDC_P003_2
- 2025-02-24
- MDC_P003_3
- 2026-05-04
- MDC_P004.de
- Condition Monitoring-Variablen für Fluoreszenzlicht-Analysator
- MDC_P004.en
- Optical fluorescence quenching sensor-specific cond. monitoring variables
- MDC_P006.de
- Merkmale, die dynamische Daten charakterisieren, bei denen es sich um Diagnosedaten handelt, welche für einen Fluoreszenzlicht-Analysator erzeugt wurden
- MDC_P006.en
- properties characterizing dynamic data which are diagnostic results generated for an optical fluorescence quenching sensor
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABP565,0112/2///61987#ABP566,0112/2///61987#ABP586,0112/2///61987#ABP587,0112/2///61987#ABP574,0112/2///61987#ABP569,0112/2///61987#ABP546,0112/2///61987#ABP547}
- MDC_P019
- false