classITEM_CLASSv1rev 12025-09-26IEC 60050:2015, 192-01-24

Reliability <of an item>

0112/2///62683#ACC008

ability to perform as required, without failure, for a given time interval, under given conditions

Inherited
10

Hierarchy#

Ancestors (top) → ACC008 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes2#

Declared properties#

No declared properties

This class does not declare any properties of its own.

Inherited properties (10) — click to expand
ACF055reliability characteristicsLIST(0,?) OF CLASS_REFERENCE_TYPE(0112/2///62683#ACC080)

ability to perform as required, without failure, for a given time interval, under given conditions

ACE053type of interlocking deviceENUM_STRING_TYPE

classification of device which prevent the hazardous operation of machine, under specified conditions (generally as long as a guard is not closed)

ACE054useful life in time intervalREAL_MEASURE_TYPE

under given conditions, the time interval beginning at a given instant of time, and ending when the failure rate becomes unacceptable

ACE455rated operational voltageLEVEL(MIN,MAX) OF INT_MEASURE_TYPE

range of voltage combined with a rated operational current intended to be switched by the device under specified conditions

ACE533rated operational current, a.c.LEVEL(MIN,MAX) OF INT_MEASURE_TYPE

range of current combined with an AC rated operational voltage intended to be switched by the device under specified conditions

ACE534rated operational current, d.c.LEVEL(MIN,MAX) OF INT_MEASURE_TYPE

range of current combined with a DC rated operational voltage intended to be switched by the device under specified conditions

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Note
Note 1 to entry: The time interval duration can be expressed in units appropriate to the item concerned, e.g. calendar time, operating cycles, distance run, etc., and the units should always be clearly stated. Note 2 to entry: Given conditions include aspects that affect reliability, such as: mode of operation, stress levels, environmental conditions, and maintenance.
Source document
IEC 60050:2015, 192-01-24
Version
1
Revision
1
Status
Standard
Publisher
IEC
Responsible committee
IEC/TC 121
Change request
C00094
Dates
  • Original: 2025-09-26
  • Current version: 2025-09-26
  • Current revision: 2025-09-26

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (39 keys from source .xls) — click to expand
C002
C00094
C011
IEC
C016
Standard
C017.de
1
C017.fr
1
C017.zh
1
C018.de
2025-09-01
C018.fr
2024-02-04
C018.zh
2025-08-05
C019.de
DKE, Silvio Foertsch
C019.fr
IEC TC 121/WG 3
C019.zh
SAC,Jia Feng
MDC_P001_5
0112/2///62683#ACC008
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2025-09-25
MDC_P003_1
2025-09-26
MDC_P003_2
2025-09-26
MDC_P003_3
2025-09-26
MDC_P004.de
Funktionsfähigkeit <einer Einheit>
MDC_P004.en
Reliability <of an item>
MDC_P004.fr
Fiabilité <d’une entité>
MDC_P004.zh
可靠性, <产品的>
MDC_P006_1
IEC 60050:2015, 192-01-24
MDC_P006.de
Fähigkeit, unter gegebenen Bedingungen und für ein gegebenes Zeitintervall wie gefordert ohne Ausfall zu funktionieren
MDC_P006.en
ability to perform as required, without failure, for a given time interval, under given conditions
MDC_P006.fr
aptitude à fonctionner tel que requis sans défaillance, pendant un intervalle de temps donné et dans des conditions données
MDC_P006.zh
在给定条件下,在给定时间区间内,按要求无失效运行的能力
MDC_P007.de
Zuverlässigkeit
MDC_P008.de
Anmerkung 1 zum Begriff: Die Dauer des Zeitintervalls kann in solchen Einheiten ausgedrückt werden, die für das betreffende Objekt angebracht sind, beispielsweise Kalenderzeit, Betriebszyklen, zurückgelegte Entfernung usw. die Einheiten sollten dabei immer eindeutig angegeben werden.
MDC_P008.en
Note 1 to entry: The time interval duration can be expressed in units appropriate to the item concerned, e.g. calendar time, operating cycles, distance run, etc., and the units should always be clearly stated. Note 2 to entry: Given conditions include aspects that affect reliability, such as: mode of operation, stress levels, environmental conditions, and maintenance.
MDC_P008.fr
Note 1 à l’article: La durée de l’intervalle de temps peut être exprimée en unités appropriées à l’entité concernée, par exemple, temps calendaire, cycles de fonctionnement, distance parcourue, etc. Il convient de toujours énoncer clairement les unités. Note 2 à l’article: Les conditions données incluent les aspects ayant un impact sur la fiabilité, tels que: le mode de fonctionnement, les niveaux de contrainte, les conditions environnementales et la maintenance.
MDC_P008.zh
注 1:时间间隔的时长可采用与相关项目相适应的单位表示,例如日历时间、运行周期、行驶距离等,且单位应始终明确标注。 注 2:给定条件包括影响可靠性的各个方面,如:运行模式、应力水平、环境条件和维护情况。
MDC_P010
0112/2///62683#ACC002
MDC_P011
ITEM_CLASS
MDC_P012
IEC/TC 121
MDC_P013
{0112/2///62683#ACC076}
MDC_P019
false
MDC_P090
{0112/2///62683#ACE006,0112/2///62683#ACF071,0112/2///62683#ACF055}

Version history1#

  1. Current rev 01
    25 Sep 2025 · 19:16 UTC by BATCH 00000840
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.